N318CF accident

NTSB ERA09CA040 · 2008-11-02 · Thomasville, NC · near N97

Docket — crew, injuries and powerplant

Summary

The pilot was making the first of a series of test flights for the new airplane. After engine run-ups and a high speed taxi run, the first takeoff was attempted. The airplane became airborne after a takeoff roll of 1,000 feet. At 30 feet AGL, the airplane would not climb higher or accelerate above 50 knots. Insufficient runway remained to land and the airplane impacted trees in a fully-stalled condition. The pilot reported there was no mechanical malfunction and the ground adjustable propeller was not set to allow the airplane to accelerate.

Full narrative

The pilot was making the first of a series of test flights for the new airplane. After engine run-ups and a high speed taxi run, the first takeoff was attempted. The airplane became airborne after a takeoff roll of 1,000 feet. At 30 feet AGL, the airplane would not climb higher or accelerate above 50 knots. Insufficient runway remained to land and the airplane impacted trees in a fully-stalled condition. The pilot reported there was no mechanical malfunction and the ground adjustable propeller was not set to allow the airplane to accelerate.

Probable cause

The builder’s failure to set adequate propeller pitch during propeller installation. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
0
Temperature (F)
72
Nearest airport
Hiatt Airport
Distance from field
0.0
Airport elevation
855

Aircraft

RegistrationMakeModelDamageFAR part
N318CF — — SUBS 091

Sequence of events

#OccurrencePhase
2 Takeoff Powerplant sys/comp malf/fail defining Takeoff

Findings

Finding
Personnel issues-Task performance-Maintenance-Installation-Owner/builder cause
Aircraft-Aircraft propeller/rotor-Propeller system-(general)-Incorrect service/maintenance cause