N555SX Davis Sonex accident

NTSB ERA09CA162 · 2009-02-06 · Crossville, TN · near CSV

Docket — crew, injuries and powerplant

Summary

The pilot of the amateur-built airplane was initiating a test flight to check a new propeller. After advancing the throttle, the airplane accelerated with normal power. However, at an altitude of 300 feet, the engine lost total power. The pilot turned back to the departure runway and landed on soft ground to the south of the runway. The landing gear collapsed, substantially damaging the firewall. Examination of the airplane revealed that continuity existed throughout the engine drivetrain, and the engine had no visible damage. The fuel was sampled and no contamination was observed. Examination of the fuel filter revealed no obstructions, the fuel pump operated normally, and the air filter was clean. The spark plugs were determined to be functional; however, no electrical energy was being delivered to the spark plugs. Further examination revealed that the electronic control unit (ECU) was not transmitting voltage to the dual coils. The ECU was manufactured to automotive specifications, and was supposed to be installed in an area of the airplane where temperatures do not exceed 65 degrees Celsius (preferably on the cabin side of the firewall). The ECU on the accident airplane was installed on the engine side of the firewall.

Full narrative

The pilot of an amateur-built Sonex airplane was initiating a test flight to check a new propeller. After advancing the throttle, the airplane accelerated with normal power. However, at an altitude of 300 feet, the experimental UL Power 260i engine lost total power. The pilot turned back to the departure runway, and landed on soft ground to the south of the runway. The landing gear collapsed, substantially damaging the firewall. Examination of the airplane revealed that continuity existed throughout the engine drive train, and the engine had no visible damage. The fuel was sampled and no contamination was observed. Examination of the fuel filter revealed no obstructions, the fuel pump operated normally, and the air filter was clean. The spark plugs were determined to be functional; however, no electrical energy was being delivered to the spark plugs. Further examination revealed that the electronic control unit (ECU) was not transmitting voltage to the dual coils. The ECU was manufactured to automotive specifications, and was supposed to be installed in an area of the airplane where temperatures do not exceed 65 degrees Celsius (preferably on the cabin side of the firewall). The ECU on the accident airplane was installed on the engine side of the firewall.

Probable cause

A total loss of engine power during initial climb due to the failure of the ignition power supply as a result of the improper installation of the electronic control unit. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
260
Wind speed (kt)
8
Temperature (F)
57
Nearest airport
Crossville Memorial Airport
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N555SX Davis Sonex SUBS 091

Sequence of events

#OccurrencePhase
1 Initial climb Powerplant sys/comp malf/fail defining Takeoff
2 Initial climb Loss of engine power (total) Takeoff

Findings

Finding
Aircraft-Aircraft power plant-Ignition system-Ignition power supply-Failure cause
Personnel issues-Task performance-Maintenance-Installation-Owner/builder cause