N11EN accident
NTSB CEN09CA521 · 2009-07-25 · Abernathy, TX · near F83
Docket — crew, injuries and powerplant
Summary
The pilot with one passenger on-board the airplane was practicing landings to familiarize the passenger with the airplane. During one of the landings, the airplane landed "firm." After noticing added noise in the cabin and the "seats being jarred” they taxied back to the hangar. The pilot reported that a fuselage tube had failed due to a "pre-existing weakened condition." The Federal Aviation Administration (FAA) Inspector who examined the airplane reported that the fuselage tube displayed evidence of corrosion.
Full narrative
The pilot with one passenger on-board the airplane was practicing landings to familiarize the passenger with the airplane. During one of the landings, the airplane landed "firm." After noticing added noise in the cabin and the "seats being jarred” they taxied back to the hangar. The pilot reported that a fuselage tube had failed due to a "pre-existing weakened condition." The Federal Aviation Administration (FAA) Inspector who examined the airplane reported that the fuselage tube displayed evidence of corrosion.
Probable cause
The failure of the fuselage's tube structure due to corrosion during a hard landing. The National Transportation Safety Board determined the probable cause of this accident.
Circumstances
- Event type
- Accident
- Highest injury
- None
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- NONE
- Ceiling (ft)
- 0
- Visibility (sm)
- 10
- Wind direction
- 190
- Wind speed (kt)
- 12
- Temperature (F)
- 81
- Nearest airport
- Abernathy Airport
- Distance from field
- 0.0
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N11EN | — | — | SUBS | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | Landing Abnormal runway contact | Cruise |
| 2 | Landing Aircraft structural failure defining | Cruise |
Findings
| Finding | |
|---|---|
| Aircraft-Aircraft structures-Fuselage-Fuselage main structure-Fatigue/wear/corrosion | cause |