N713DW Weber PELICAN accident

NTSB CEN09LA551 · 2009-08-26 · Searcy, AR · near SRC

Docket — crew, injuries and powerplant

Summary

The pilot took off for a test flight and after climbing approximately 500 feet, and with about 1,000 to 1,500 feet of runway remaining, the engine lost power. The pilot lowered the nose to maintain airspeed and made a forced landing in a field at the end of the runway. Upon touchdown, the landing gear collapsed and the airplane skidded a few feet before coming to a stop. Postaccident examination indicated that the fuel selector was in the "OFF" position; the pilot thought it was in the "ON" position. The design of the selector handle was such that the "tail" of the selector handle was in the "OFF" position. A 180-degree twist of the handle would have placed it in the "ON" position.

Full narrative

On August 26, 2009, approximately 1225 central daylight time, a Weber Pelican PL, N713DW, piloted by a commercial pilot, was substantially damaged when it impacted terrain following a loss of engine power shortly after taking off from Searcy, Arkansas, Municipal Airport (SRC). Visual meteorological conditions prevailed at the time of the accident. The flight was being conducted under the provisions of Title 14 Code of Federal Regulations (CFR) Part 91 without a flight plan. The pilot, the sole occupant on board, was not injured. The local test flight was originating at the time of the accident.

According to the pilot’s accident report, all preflight and pre-takeoff checks were accomplished and he took off on runway 19 for a local test flight. After climbing approximately 500 feet with about 1,000 to 1,500 feet of runway remaining, the engine “missed once” and lost power. He lowered the nose to maintain airspeed and made a forced landing in a field at the end of the runway. Upon touchdown, the landing gear collapsed and the airplane skidded a few feet before coming to a stop.

An FAA airworthiness inspector went to the scene and reported finding the fuel selector in the OFF position. He said the pilot thought it was in the ON position. The inspector said the design of the fuel selector handle was poor because the “tail” of the selector handle was in the OFF position. A 180-degree twist of the handle would have placed it in the ON position.

Probable cause

A total loss of engine power due to fuel starvation as a result of the pilot's incorrect positioning of the fuel selector valve. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
150
Wind speed (kt)
4
Temperature (F)
88
Nearest airport
Searcy Municipal
Distance from field
0.0
Airport elevation
264

Aircraft

RegistrationMakeModelDamageFAR part
N713DW Weber PELICAN SUBS 091

Sequence of events

#OccurrencePhase
1 Initial climb Fuel starvation defining Takeoff
2 Initial climb Loss of engine power (total) Takeoff
3 Emergency descent Off-field or emergency landing Descent
4 Landing-landing roll Collision with terr/obj (non-CFIT) Cruise

Findings

Finding
Aircraft-Aircraft systems-Fuel system-Fuel selector/shutoff valve-Incorrect use/operation cause
Personnel issues-Action/decision-Action-Incorrect action performance-Pilot cause
Personnel issues-Task performance-Use of equip/info-Use of equip/system-Pilot cause
Aircraft-Fluids/misc hardware-Fluids-Fuel-Fluid management cause