N639ME Eurocopter Deutschland Gmbh EC 135 accident

NTSB ERA16CA060 · 2015-11-06 · Monongahela, PA · near 5PA5

Docket — crew, injuries and powerplant

Summary

After liftoff during a helicopter emergency medical service (HEMS) flight with a patient on board, the pilot of the HEMS helicopter brought it in to a 1 to 2 foot hover and was preparing to make a right pedal turn into the wind, when a cover from a wheeled fire extinguisher, was blown airborne by the main rotor wash and ingested into the tail rotor (fenestron) of the helicopter. The helicopter lost tail rotor authority and began to spin clockwise. The pilot lowered the collective and the helicopter rotated approximately 150 degrees, then impacted the ground and continued to rotate another 20 to 30 degrees, for a total of 170 to180 degree turn, and came to rest. Examination of the helicopter by a Federal Aviation Administration inspector revealed damage to the landing gear skid tubes, fenestron composite housing, and the forward cross tube gimbal which had pushed up into a composite non-structural area of the fuselage. It was discovered, that the wheeled fire extinguisher that the cover had blown off of, had been inspected for serviceability just four days prior to the accident.

Full narrative

After liftoff during a helicopter emergency medical service (HEMS) flight with a patient on board, the pilot of the HEMS helicopter brought it in to a 1 to 2 foot hover and was preparing to make a right pedal turn into the wind, when a cover from a wheeled fire extinguisher, was blown airborne by the main rotor wash and ingested into the tail rotor (fenestron) of the helicopter. The helicopter lost tail rotor authority and began to spin clockwise. The pilot lowered the collective and the helicopter rotated approximately 150 degrees, then impacted the ground and continued to rotate another 20 to 30 degrees, for a total of 170 to180 degree turn, and came to rest. Examination of the helicopter by a Federal Aviation Administration inspector revealed damage to the landing gear skid tubes, fenestron composite housing, and the forward cross tube gimbal which had pushed up into a composite non-structural area of the fuselage. It was discovered, that the wheeled fire extinguisher that the cover had blown off of, had been inspected for serviceability just four days prior to the accident.

Probable cause

The inadequate securing of the wheeled fire extinguisher's cover which resulted in it being blown off of the fire extinguisher and ingested into the helicopter's fenestron during takeoff, resulting in a loss of directional control. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Dawn
Sky condition
BKN
Ceiling (ft)
12000
Visibility (sm)
10
Wind direction
180
Wind speed (kt)
9
Temperature (F)
66
Nearest airport
MONONGAHELA VALLEY HOSPITAL
Distance from field
0.0
Airport elevation
1114

Aircraft

RegistrationMakeModelDamageFAR part
N639ME EUROCOPTER DEUTSCHLAND GMBH EC 135 SUBS 135

Sequence of events

#OccurrencePhase
1 Takeoff Miscellaneous/other Takeoff
2 Takeoff Loss of control in flight defining Takeoff
3 Landing Hard landing Cruise

Findings

Finding
Environmental issues-Physical environment-Object/animal/substance-Debris/dirt/foreign object-Effect on equipment cause
Aircraft-Aircraft propeller/rotor-Tail rotor-Tail rotor blade-Damaged/degraded cause
Aircraft-Aircraft oper/perf/capability-Performance/control parameters-Directional control-Attain/maintain not possible cause