N500TN Hughes 369 accident

NTSB GAA16CA480 · 2016-09-09 · Peach Orchard, MO

Docket — crew, injuries and powerplant

Summary

The helicopter pilot reported that he was flying in support of a utility company crew that was installing line guards for a conductor damper on an energized 161 kilovolts (Kv) electrical transmission line. The transmission line had three phases (power lines) that were separated vertically and staggered horizontally from one another and ran parallel to the ground. The lower phase power line was about 9.5 ft (horizontally) further out from the middle phase power line. While the helicopter was approaching the lines, its main rotor blade clearance from the middle phase line was about 2.5 ft, which resulted in an electrical arc to the main rotor. The pilot landed the helicopter away from the transmission line without further incident. A postaccident examination revealed substantial damage to the main rotor hub and two main rotor blades. The pilot reported no preaccident mechanical malfunctions or failures with the helicopter that would have precluded normal operation. According to Occupational Safety & Health Administration 1910.269(I)(10), the minimum approach distance (MAD) is to "ensure that workers do not approach or take any conductive object closer to the energized parts as set forth in the table below (excerpt)." For a voltage of 161 Kv, the MAD for this operation was equal to or greater than 4.00625 ft.

Full narrative

The helicopter pilot reported that he was flying in support of a utility company crew that was installing line guards for a conductor damper on an energized 161 kilovolts (Kv) electrical transmission line. The transmission line had three phases (power lines) that were separated vertically and staggered horizontally from one another and ran parallel to the ground. The lower phase power line was about 9.5 feet (horizontally) further out from the middle phase power line. During approach to the lines, the main rotor blade clearance from the middle phase line was about 2.5 feet, which resulted in an electrical arc to the main rotor. The pilot landed the helicopter away from the transmission line without further incident.

A postaccident examination revealed substantial damage to the main rotor hub and two main rotor blades.

The pilot reported no preaccident mechanical malfunctions or failures with the helicopter that would have precluded normal operation.

According to the Occupational Safety & Health Administration (OSHA) 1910.269(I)(10) the Minimum Approach Distances (MAD) is to "ensure that workers do not approach or take any conductive object closer to the energized parts as set forth in the table below (excerpt). "

Nominal voltage in kilovolts Distance: Phase to ground exposure (feet)

161 to 169 4.00625

The MAD for this operation was a distance equal to or greater than 4.00625 feet.

Probable cause

The helicopter pilot’s failure to maintain sufficient separation between the main rotor blade and a power line during line guard installation, which resulted in an electrical arc to the main rotor. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
BKN
Ceiling (ft)
3700
Visibility (sm)
10
Wind direction
230
Wind speed (kt)
8
Temperature (F)
93
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N500TN HUGHES 369 SUBS 133

Sequence of events

#OccurrencePhase
1 Maneuvering-hover Miscellaneous/other defining Climb

Findings

Finding
Personnel issues-Psychological-Attention/monitoring-Monitoring environment-Pilot cause
Environmental issues-Physical environment-Object/animal/substance-Wire-Effect on operation cause
Personnel issues-Task performance-Use of equip/info-Use of policy/procedure-Pilot factor