N245DK Balony Kubicek Spol Sro BB70Z accident

NTSB GAA17CA262 · 2017-04-22 · Park City, UT

Docket — crew, injuries and powerplant

Summary

The pilot reported that the wind shifted before departure and that, although this would result in the balloon travelling to an area with "limited landing opportunities," he chose to continue the departure. During landing, the balloon descended to about 20 to 30 ft above the ground, and the landing area was on a hillside that had a commercial building on the top and that, at the base of the hill, was a short pole with guy wires. He did not see any other poles, so he "focused" on the intended landing site. As the balloon approached the landing site, a passenger asked, "if we would hit that power line?" He looked up and saw two power lines above and forward of the balloon's path, and he immediately vented the balloon to land and stop its forward progress. The balloon collided with the power lines and settled to the ground. The balloon sustained substantial damage to 3 of its 24 cables that attach the envelope to the basket. The pilot reported that there were no preaccident mechanical failures or malfunctions with the balloon that would have precluded normal operation.

Full narrative

The pilot reported that the wind shifted before departure and the balloon would travel to an area with "limited landing opportunities", but he elected to continue the departure. During landing, the balloon descended to approximately 20-30 ft. above the ground, and the landing area was on a dry hillside just past a wetland. He added that the hillside had a commercial building on the top, and at the base of the hill was a short pole with guy-wires. He did not see any other poles, so he "focused" on the intended landing site. As the balloon approached the landing site, a passenger asked, "if we would hit that powerline?" He looked up and saw two powerlines above and forward of the balloon's path, and he immediately vented the balloon to land and stop their forward progress. The balloon collided with the powerlines and settled to the ground.

The balloon sustained substantial damage to 3 of its 24 cables that attach the envelope to the basket.

The pilot reported that there were no preaccident mechanical failures or malfunctions with the balloon that would have precluded normal operation.

Probable cause

The pilot’s failure to see and avoid power lines during landing. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
0
Wind speed (kt)
4
Temperature (F)
45
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N245DK BALONY KUBICEK SPOL SRO BB70Z SUBS 091

Sequence of events

#OccurrencePhase
1 Landing Off-field or emergency landing Cruise
2 Landing Miscellaneous/other Cruise
3 Landing Loss of control in flight defining Cruise
4 Landing Collision with terr/obj (non-CFIT) Cruise

Findings

Finding
Aircraft-Aircraft oper/perf/capability-Performance/control parameters-Altitude-Not attained/maintained cause
Personnel issues-Psychological-Attention/monitoring-Monitoring environment-Pilot cause
Personnel issues-Action/decision-Info processing/decision-Decision making/judgment-Pilot factor
Environmental issues-Physical environment-Object/animal/substance-Wire-Effect on equipment factor
Aircraft-Aircraft oper/perf/capability-Performance/control parameters-Descent/approach/glide path-Not attained/maintained factor