N7085R Piper PA 28 accident

NTSB GAA18CA102 · 2018-01-13 · Corona, CA

Docket — crew, injuries and powerplant

Summary

According to the flight instructor, during an off-airport simulated engine failure with a 180° turn, he called for a go-around upon completion of the maneuver. The student initiated the go-around, but the airplane struck power line wires. The flight instructor landed the airplane in a field, and the nose landing gear separated from the airplane. The airplane sustained substantial damage to the engine mounts. The flight instructor reported that this accident could have been prevented by performing a ground reconnaissance of unfamiliar practice areas to assess for hazards to flight. The flight instructor will also initiate simulated engine failures at a higher altitude to enable recovery at no less than 500ft above ground level. The pilot reported that there were no preaccident mechanical malfunctions or failures with the airplane that would have precluded normal operation.

Full narrative

According to the flight instructor, during an off-airport simulated engine failure with a 180° turn, he called for a go-around upon completion of the maneuver.

The student initiated the go-around, but the airplane struck powerline wires. The flight instructor landed the airplane in a field, and the nose landing gear separated from the airplane.

The airplane sustained substantial damage to the engine mounts.

Per the National Transportation Safety Board's Pilot Aircraft Accident Report, the pilot reported in the Safety Recommendation section, that this accident could have been prevented by performing a ground reconnaissance of unfamiliar practice areas to assess for hazards to flight. The flight instructor will also initiate simulated engine failures at a higher altitude, to enable a go-around at no less than 500ft above ground level.

The pilot reported that there were no preaccident mechanical malfunctions or failures with the airplane that would have precluded normal operation.

Probable cause

The student pilot and flight instructor’s failure to see and avoid powerlines during a simulated emergency landing, which resulted in a wire strike during a go-around. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
110
Wind speed (kt)
12
Temperature (F)
81
Distance from field
0.0
Airport elevation
533

Aircraft

RegistrationMakeModelDamageFAR part
N7085R PIPER PA 28 SUBS 091

Sequence of events

#OccurrencePhase
1 Maneuvering-low-alt flying Simulated/training event defining Climb
2 Approach-VFR go-around Collision with terr/obj (non-CFIT) Cruise
3 Landing Part(s) separation from AC Cruise

Findings

Finding
Personnel issues-Psychological-Attention/monitoring-Monitoring environment-Student/instructed pilot cause
Environmental issues-Physical environment-Object/animal/substance-Wire-Effect on operation cause
Personnel issues-Psychological-Attention/monitoring-Monitoring environment-Instructor/check pilot cause