N947RC J&J Ultralights Sea-Wing accident
NTSB ERA21LA051 · 2020-11-22 · Placida, FL
Docket — crew, injuries and powerplant
Factual narrative
The pilot departing from a road in the weight-shift control aircraft. At takeoff, the aircraft “pulled to the left” and struck a tree off the paved surface as the pilot aborted the takeoff. Afterwards, the pilot stated there were no mechanical deficiencies with the aircraft that would have precluded normal operations, and that the pull was likely due to an improperly adjusted wingtip.
Probable cause
The pilot/owner’s improper preflight inspection of the weight-shift trike, which resulted in a loss of control at takeoff due to an improperly adjusted wingtip. The National Transportation Safety Board determined the probable cause of this accident.
Circumstances
- Event type
- Accident
- Highest injury
- Serious
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- NONE
- Ceiling (ft)
- 0
- Visibility (sm)
- 10
- Wind direction
- 10
- Wind speed (kt)
- 6
- Temperature (F)
- 75
- Distance from field
- 0.0
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N947RC | J&J Ultralights | Sea-Wing | SUBS | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 4 | Takeoff-rejected takeoff Collision during takeoff/land defining | Takeoff |
Findings
| Finding | |
|---|---|
| Aircraft-Aircraft structures-Wing structure-Flight surfaces (wing)-Inadequate inspection | cause |
| Personnel issues-Task performance-Inspection-Preflight inspection-Pilot | cause |