N42JM North American-Buehn T-6G accident

NTSB CEN23LA192 · 2023-05-20 · Ankeny, IA · near KIKV

Docket — crew, injuries and powerplant

Factual narrative

The pilot reported he completed the landing checklist on the downwind leg and confirmed that the landing gear was extended via the cockpit landing gear indicator lights. Additionally, he saw that the landing gear locking pins were engaged. On final approach, the pilot intended to move the flap control lever to the “full down” position; however, he inadvertently moved the landing gear control lever from the “down” position. The pilot did not perform a visual gear down check on short final. The airplane touched down with its main landing gear retracted and came to a stop on the runway. The pilot and his passenger exited the airplane and a post-accident fire ensued. The fuselage and left wing were substantially damaged by the fire. The pilot reported that there were no preaccident mechanical failures or malfunctions with the airplane that would have precluded normal operation.

Probable cause

The pilot’s inadvertent retraction of the landing gear control lever, resulting in a gear-up landing on the runway. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
9
Wind direction
0
Temperature (F)
61
Nearest airport
Ankeny municipal Airport
Distance from field
0.0
Airport elevation
910

Aircraft

RegistrationMakeModelDamageFAR part
N42JM NORTH AMERICAN-BUEHN T-6G SUBS 091

Sequence of events

#OccurrencePhase
1 Landing Landing gear collapse defining Cruise
2 Landing-flare/touchdown Landing gear not configured Cruise

Findings

Finding
Aircraft-Aircraft systems-Landing gear system-Main landing gear-Unintentional use/operation cause
Personnel issues-Action/decision-Action-Incorrect action selection-Pilot cause