N5236R Aerostar International Inc S53A accident

NTSB CEN24LA139 · 2024-03-21 · Rochester, MN

Docket — crew, injuries and powerplant

Factual narrative

The pilot reported that as he was attempting to land the hot air balloon in a field, the wind shifted and increased in speed. The pilot attempted to abort the landing but was unable to arrest the ballon’s descent. The balloon contacted power lines which resulted in an electrical arc and a shower of sparks. The arc severed 12 of the 16 flying wires, and the remaining flying wires failed in a manner consistent with overload. The basket separated from the envelope and came to rest on its side. The balloon sustained substantial damage to the flying wires, attachment hardware, and the basket support structure. The pilot reported that there were no preaccident mechanical malfunctions or failures with the balloon that would have precluded normal operation. The wind at the time of the accident was 350° at 9 knots.

Probable cause

The pilot’s failure to maintain clearance from power lines while landing in a field. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
350
Wind speed (kt)
9
Temperature (F)
27
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N5236R AEROSTAR INTERNATIONAL INC S53A SUBS 091

Sequence of events

#OccurrencePhase
2 Approach-VFR go-around Collision during takeoff/land defining Cruise

Findings

Finding
Aircraft-Aircraft oper/perf/capability-Performance/control parameters-Altitude-Not attained/maintained cause
Environmental issues-Physical environment-Object/animal/substance-Wire-Ability to respond/compensate factor
Environmental issues-Conditions/weather/phenomena-Wind-(general)-Effect on operation factor
Personnel issues-Psychological-Attention/monitoring-Monitoring environment-Pilot cause