N5236R Aerostar International Inc S53A accident
NTSB CEN24LA139 · 2024-03-21 · Rochester, MN
Docket — crew, injuries and powerplant
Factual narrative
The pilot reported that as he was attempting to land the hot air balloon in a field, the wind shifted and increased in speed. The pilot attempted to abort the landing but was unable to arrest the ballon’s descent. The balloon contacted power lines which resulted in an electrical arc and a shower of sparks. The arc severed 12 of the 16 flying wires, and the remaining flying wires failed in a manner consistent with overload. The basket separated from the envelope and came to rest on its side. The balloon sustained substantial damage to the flying wires, attachment hardware, and the basket support structure. The pilot reported that there were no preaccident mechanical malfunctions or failures with the balloon that would have precluded normal operation. The wind at the time of the accident was 350° at 9 knots.
Probable cause
The pilot’s failure to maintain clearance from power lines while landing in a field. The National Transportation Safety Board determined the probable cause of this accident.
Circumstances
- Event type
- Accident
- Highest injury
- Minor
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- NONE
- Ceiling (ft)
- 0
- Visibility (sm)
- 10
- Wind direction
- 350
- Wind speed (kt)
- 9
- Temperature (F)
- 27
- Distance from field
- 0.0
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N5236R | AEROSTAR INTERNATIONAL INC | S53A | SUBS | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 2 | Approach-VFR go-around Collision during takeoff/land defining | Cruise |