N7967Y accident

NTSB CEN25LA015 · 2024-10-16 · New Orleans, LA · near NEW

Docket — crew, injuries and powerplant

Factual narrative

The pilot reported that while on approach he extended the landing gear, and the three green landing gear indication lights were illuminated; however, he noted that the gear took longer to extend than expected. There was a minimal crosswind, the wind was not gusting, and he lowered the right wing into the crosswind. Upon touch down, the right wing dropped and contacted the runway then the nose gear collapsed, and the gear warning horn sounded. The airplane continued off the right side of the runway and came to rest upright in the grass. The airplane sustained substantial damage to the fuselage and right wing spar. Postaccident examination of the airplane revealed that the left torque arm for right gear and nose gear was broken. The nose gear push pull rod and rod end for the right gear push pull cable was detached from the left torque arm. The right torque arm for the left gear was intact. The rod end for the left gear push pull cable was still attached and functional.

Probable cause

The failure of a landing gear torque arm which resulted in a landing gear collapse and runway excursion. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
40
Wind speed (kt)
22
Temperature (F)
59
Nearest airport
LAKEFRONT
Distance from field
0.0
Airport elevation
7

Aircraft

RegistrationMakeModelDamageFAR part
N7967Y — — SUBS 091

Sequence of events

#OccurrencePhase
1 Landing-landing roll Landing gear collapse defining Cruise

Findings

Finding
Aircraft-Aircraft systems-Landing gear system-Gear extension and retract sys-Failure cause