N2355Y Cessna 177 accident

NTSB SEA99LA025 · 1998-12-26 · BELLINGHAM, WA · near BLI

Docket — crew, injuries and powerplant

Summary

The pilot stated that shortly after takeoff, during the ascent, he encountered instrument meteorological conditions at 500 feet AGL, and initiated a turn back to the airport. During the turn, the aircraft lost a considerable amount of altitude and collided with multiple tree tops. The pilot was able to continue to the airport and land without further incident. The pilot stated he did not receive a formal weather briefing from a flight service station and relied solely on the automated surface observation system report at the airport.

Full narrative

On December 25, 1998, about 1845 Pacific standard time, a Cessna 177 Cardinal, N2355Y, registered to and operated by the pilot as a 14 CFR Part 91 pleasure flight, was substantially damaged after colliding with tree tops shortly after departure from the Bellingham Airport (BLI), Bellingham Washington. Night visual meteorological conditions prevailed and no flight plan was filed. The private pilot and his passenger were uninjured. There was no fire, and no report of an ELT actuating. The flight originated from the Bellingham Airport approximately 10 minutes prior to the accident.

The pilot stated that shortly after take off, during the ascent, he encountered instrument meteorological conditions at approximately 500 feet above ground level and initiated a turn back to the airport. The pilot stated that "During the turn, I apparently overreacted and increased the bank angle to the extent that it began losing altitude. My instrument scan was poor and I realize now that I was spending too much time looking outside for ground reference." The pilot leveled the wings. However, the airplane continued to descend and collided with tree tops. The pilot was able to continue to the airport and land without further incident. The pilot also stated he did not receive a formal weather briefing from a flight service station and relied solely on the automated weather observing system report at the Bellingham airport.

At 1856, the Bellingham automated weather observing system was reporting wind from 350 degrees at eight knots. Visibility was four miles with light rain. The sky condition was reported as a few clouds at 800 feet and overcast at 1,400 feet.

Probable cause

Inadequate preflight planning/preparation, and the pilot's failure to maintain altitude. VFR flight into IMC conditions and cloudy weather conditions were factors. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Night/Dark
Sky condition
OVC
Ceiling (ft)
1400
Visibility (sm)
7
Wind direction
329
Wind speed (kt)
8
Temperature (F)
36
Nearest airport
BELLINGHAM INTERNATIONAL
Distance from field
1.0
Airport elevation
166

Aircraft

RegistrationMakeModelDamageFAR part
N2355Y Cessna 177 SUBS 091

Sequence of events

#OccurrencePhase
1 240 Cruise
2 220 Cruise

Findings

Finding
20000 factor
24001 cause
24015 factor
20200
24526 cause