N3836C Aero Commander 500 accident

NTSB MIA93IA083 · 1993-03-07 · EVERGLADES CITY, FL · near XO1

Docket — crew, injuries and powerplant

Factual narrative

THE AIRLINE TRANSPORT PILOT-IN-COMMAND ABORTED THE TAKEOFF WHEN A PROPELLER BLADE FROM THE RIGHT ENGINE SEPARATED FROM THE RIGHT PROPELLER SYSTEM. EXAMINATION OF THE PROPELLER HUB BY THE NTSB MATERIALS LABORATORY DIVISION REVEALED THE PROPELLER HUB ARM FAILED DUE TO PREEXISTING FATIGUE CRACKING IN THE BEARING RETENTION RADIUS, FROM POLISHING AND WEAR OF THE RADIUS FROM CONTACT WITH THE SPLIT RINGS.

Probable cause

THE PREEXISTING FATIGUE CRACKING OF THE PROPELLER HUB ARM IN THE BEARING RETENTION RADIUS DUE TO POLISHING AND WEAR OF THE RADIUS FROM CONTACT WITH THE SPLIT RINGS, RESULTING IN A PROPELLER BLADE SEPARATING FROM THE PROPELLER HUB ON THE TAKEOFF GROUND RUN, AND SUBSEQUENT ABORTED TAKEOFF. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
BKN
Ceiling (ft)
25000
Wind direction
150
Wind speed (kt)
6
Temperature (F)
79
Nearest airport
EVERGLADES
Distance from field
0.0
Airport elevation
5

Aircraft

RegistrationMakeModelDamageFAR part
N3836C AERO COMMANDER 500 MINR 135

Sequence of events

#OccurrencePhase
1 130 Cruise

Findings

Finding
14502
14502 cause