N343UA Boeing 737-300 accident

NTSB DEN92IA025 · 1992-01-03 · DENVER, CO

Docket — crew, injuries and powerplant

Factual narrative

DURING CLIMB, THE CREW NOTED AN ELECTRICAL ARCING SOUND AND SLIGHT ELECTRICAL-TYPE BURNING ODOR WHILE PASSING THROUGH FLIGHT LEVEL 180. EMERGENCY PROCEDURES WERE COMPLIED WITH AND THE PROBLEM APPEARED TO BE SOLVED. THE CLIMB WAS CONTINUED, AND WHILE PASSING THROUGH FLIGHT LEVEL 330 A LOUD ARCING SOUND WAS AGAIN HEARD ACCOMPANIED BY FLAMES FROM THE FLIGHT DECK AFT OVERHEAD PANEL. THE FLIGHT ATTENDANTS EXTINGUISHED THE FIRE, AND THE FLIGHT RETURNED TO DENVER AND LANDED WITHOUT FURTHER INCIDENT. EXAMINATION DISCLOSED A SHORT IN A WIRE BUNDLE. THE BUNDLE WAS NOT SHIELDED OR ANCHORED AS THE OTHER MAJOR BUNDLE IN THE COMPARTMENT. THE SHORT WAS DUE TO THE BUNDLE CHAFING ON THE FLIGHT DECK ENTRY DOOR FRAME. IN ADDITION, TESTING REVEALED THAT THE WIRE GAUGE USED IN PART OF THIS APPLICATION WAS INSUFFICIENT FOR THE ELECTRICAL LOAD.

Probable cause

AN ELECTRICAL SHORT CIRCUIT IN A MAIN WIRE BUNDLE DUE TO CHAFING OF THE BUNDLE ON AIRFRAME STRUCTURAL MEMBERS. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
99
Wind direction
190
Wind speed (kt)
7
Temperature (F)
48
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N343UA BOEING 737-300 MINR 121

Sequence of events

#OccurrencePhase
1 171 Cruise

Findings

Finding
12013 cause
12013 cause
12013 cause