N4942X Rockwell S-2R accident

NTSB MIA92LA094 · 1992-03-07 · HOLLANDALE, MS

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT WAS REFUELED BEFORE DEPARTURE WITH THE ENG RUNNING BUT THE PLT DID NOT CHECK THE FUEL TANK FOR CONTAMINANTS. AFTER TAKEOFF DURING CRUISE FLT, THE ENG QUIT. THE PLT ATTEMPTED TO LAND ON A ROAD BUT THE ACFT COLLIDED WITH A BUILDING THEN THE GROUND. APRX 4 OUNCES OF FUEL WAS DRAINED FROM THE FUEL CONTROLLER OF WHICH 2 OUNCES WAS WATER.

Probable cause

FAILURE OF THE PILOT IN COMMAND TO CHECK THE FUEL TANK FOR CONTAMINANTS BEFORE DEPARTURE, WHICH RESULTED IN THE TOTAL LOSS OF ENGINE POWER DUE TO WATER CONTAMINATION. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
20
Wind direction
270
Wind speed (kt)
5
Temperature (F)
81
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N4942X Rockwell S-2R SUBS 137

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 220 Cruise
4 230 Cruise

Findings

Finding
17001 cause
24002 cause
20200