N6892K Schweizer G-164B accident

NTSB LAX92LA325 · 1992-07-30 · VISALIA, CA · near Q31

Docket — crew, injuries and powerplant

Factual narrative

THE PILOT SAID HE WAS ON THE TAKEOFF GROUND ROLL WHEN AN AEROSOL SPRAY CAN, WHICH WAS SITTING ON THE REAR OF THE GLARE SHIELD, SHORTED ACROSS TWO ELECTRICAL TERMINALS. ELECTRICAL ARCING PUNCTURED THE SPRAY CAN AND THE CONTENTS BURST INTO FLAMES. THE PILOT ABORTED THE TAKEOFF AND THE AIRCRAFT GROUND LOOPED DURING THE PILOT'S ATTEMPT TO STOP THE AIRCRAFT PRIOR TO THE END OF THE RUNWAY.

Probable cause

THE PILOT'S IMPROPER STOWAGE OF AN AEROSOL SPRAY CAN IN THE COCKPIT WHICH CAUSED AN ELECTRICAL SHORT AND AN ENSUING FIRE, AND HIS FAILURE TO MAINTAIN DIRECTIONAL CONTROL OF THE AIRCRAFT DURING THE SUBSEQUENT ABORTED TAKEOFF. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
310
Wind speed (kt)
5
Temperature (F)
97
Nearest airport
SEQUOIA FIELD
Distance from field
0.0
Airport elevation
316

Aircraft

RegistrationMakeModelDamageFAR part
N6892K SCHWEIZER G-164B SUBS 137

Sequence of events

#OccurrencePhase
1 171 Cruise
2 320 Cruise

Findings

Finding
12000
17100
24035 cause
24539 cause
24537 cause