N62404 Hiller-Soloy UH12D accident

NTSB SEA92LA152 · 1992-07-14 · LOMAN, ID

Docket — crew, injuries and powerplant

Factual narrative

WHILE THE HILLER/SOLOY UH12D WAS REPOSITIONING LOGGING PERSONNEL, IT EXPERIENCED A TOTAL LOSS OF POWER. BECAUSE THERE WAS NO SUITABLE LANDING AREA, THE PILOT ELECTED TO ATTEMPT AN AUTOROTATION INTO THE TOP OF THE TREES, WHICH STOOD APPROXIMATELY 50 FEET HIGH. AFTER IMPACTING THE TOP OF THE TREES, THE HELICOPTER FELL TO THE GROUND. AFTER THE CRASH IT WAS FOUND THAT A SHORT IN THE FUEL QUANTITY TRANSMITTER UNIT HAD CAUSED THE FUEL GAUGE TO READ 20 GALLONS, WHEN THE TANK ACTUALLY HAD ABOUT ONE CUP OF FUEL REMAINING.

Probable cause

FUEL EXHAUSTION. FACTORS INCLUDE A SHORT IN THE FUEL QUANTITY SENSOR/TRANSMITTER, AN INADEQUATE PREFLIGHT, AND A TREE COVERED LANDING AREA. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
20
Wind direction
0
Temperature (F)
70
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N62404 Hiller-Soloy UH12D SUBS 091

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 220 Cruise

Findings

Finding
17001 cause
15128 factor
24001 cause
20200 factor