N401DA Boeing 727-232 accident

NTSB CHI93LA043 · 1992-11-28 · CHICAGO, IL

Docket — crew, injuries and powerplant

Factual narrative

THE FLIGHT HAD ARRIVED AT THE JETWAY AND THE PASSENGERS WERE BEGINNING TO DEPLANE. BEFORE EXTERNAL GROUND POWER WAS SUPPLIED TO THE AIRPLANE, THE CAPT PREMATURELY SHUT DOWN THE NUMBER ONE ENGINE WHICH WAS SUPPLYING ELECTRICAL POWER TO THE CABIN. WHEN THE ENGINE WAS SHUT DOWN, THE MAIN CABIN LIGHTS WENT OUT, FOLLOWED IMMEDIATELY BY THE ILLUMINATION OF THE BATTERY-POWERED EMERGENCY FLOOR LIGHTS. THE FLIGHT ENGINEER ANNOUNCED TO THE CAPT THAT HE WAS STARTING THE AUXILIARY POWER UNIT (APU). AS HE STARTED THE APU, AN EXHAUST FLAME MOMENTARILY CAME OUT FROM THE APU EXHAUST PIPE LOCATED NEAR THE TOP OF THE RIGHT WING ROOT. SOME PASSENGERS YELLED 'FIRE' AND BEGAN AN UNCOMMANDED EVACUATION THROUGH THE OVERWING EXITS. CREW MEMBERS WERE ABLE TO STOP THE EVAUCATION, BUT NOT BEFORE SEVERAL PASSENGERS HAD JUMPED OFF THE WINGS AND INCURRED INJURIES.

Probable cause

THE CAPTAIN'S INADEQUATE COORDINATION WITH THE GROUND AND FLIGHT CREW. FACTORS RELATED TO THE ACCIDENT WERE: THE PASSENGER'S PERCEPTION THAT THE APU EXHAUST WAS A FIRE, WHICH RESULTED IN ACTION THAT INITIATED AN EVACUATION. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Serious
Weather conditions
Visual Meteorological Cond
Light condition
Night/Dark
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
8
Wind direction
220
Wind speed (kt)
7
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N401DA BOEING 727-232 — 121

Sequence of events

#OccurrencePhase
1 430 Cruise

Findings

Finding
16902
17203
22403 factor
23303
24712 factor
24624 cause
31210 factor