N65418 Cessna 152 accident

NTSB MIA91LA068 · 1991-01-17 · MIAMI, FL

Docket — crew, injuries and powerplant

Factual narrative

THREE DAYS BEFORE THE ACCIDENT FLT, THE VACUUM PUMP WAS REMOVED AND HAD NOT BEEN REINSTALLED. THE CFI & STUDENT PREFLIGHTED THE ACFT WITH NO DISCREPANCIES NOTED. THE ENGINE START & RUN-UP PRIOR TO DEPARTURE WERE REPORTED AS NORMAL. THE FLT DEPARTED & THE CFI STATED THAT THE ENG WOULD NOT DEVELOP POWER GREATER THAN 1,200 RPM. DURING THE FORCED LANDING ON A ROAD, THE NOSE GEAR TRAVELLED INTO A DITCH & THE ACFT NOSED OVER. EXAM OF THE ACFT AT THE ACCIDENT SITE, REVEALED OIL COATED THE BOTTOM OF THE FUSELAGE.

Probable cause

INADEQUATE MAINTENANCE RECORD KEEPING BY THE OPERATION, AND FAILURE OF THE CFI TO FOLLOW PROCEDURES AND DIRECTIVES. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
BKN
Ceiling (ft)
5000
Visibility (sm)
8
Wind direction
360
Wind speed (kt)
14
Temperature (F)
66
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N65418 CESSNA 152 SUBS 091

Sequence of events

#OccurrencePhase
1 350 Cruise
2 180 Cruise
3 320 Cruise
4 300 Cruise

Findings

Finding
14901
17002
24118 cause
24032 cause
19200