N4596W Rockwell 112TC accident

NTSB FTW91LA106 · 1991-06-21 · OVILLA, TX

Docket — crew, injuries and powerplant

Factual narrative

UPON DEPARTING THE AIRPORT A TOTAL POWER LOSS WAS EXPERIENCED. AN ATTEMPTED RETURN TO THE AIRPORT WAS UNSUCCESSFUL AND RESULTED IN A FORCED LANDING IN AN OPEN FIELD. SUBSEQUENT EXAMINATION OF THE WRECKAGE REVEALED THAT THE TURBOCHARGER HAD MALFUNCTIONED RESULTING IN THE POWER LOSS. AFTER A HARD LANDING THE MAIN LANDING GEAR COLLAPSED. A SMALL POST-IMPACT FIRE DEVELOPED IN A BALE OF HAY BUT WAS EXTINGUISHED BY THE FIRE DEPARTMENT. ALTHOUGH AN ANNUAL INSPECTION HAD BEEN PERFORMED 57 HOURS PRIOR TO THE ACCIDENT, THE EXHAUST SYSTEM WAS IN POOR CONDITION AND THE TURBOCHARGER WASTE GATE WAS BADLY CORRODED.

Probable cause

THE MECHANICAL FAILURE OF THE TURBOCHARGER. FACTORS WERE THE INADEQUATE ANNUAL INSPECTION AND THE PILOT'S IMPROPER FLARE IN THE FORCED LANDING. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
135
Temperature (F)
75
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N4596W ROCKWELL 112TC SUBS 091

Sequence of events

#OccurrencePhase
1 352 Cruise
2 180 Cruise
3 200 Cruise
4 191 Cruise

Findings

Finding
14416 cause
14419
24104 factor
24535 factor
10401