N339TE British Aerospace 3201 accident

NTSB CHI91MA260 · 1991-08-12 · ST LOUIS, MO · near STL

Docket — crew, injuries and powerplant

Factual narrative

DRG FLT, A HYDR LINE (PN 137311D1443) IN THE MAIN HYDR SYS FAILED. THE CAPT & 1ST OFFICER MADE NUMEROUS ATMTS TO EXTD THE LNDG GEAR BY USING THE EMERG CHECKLIST & ACFT FLT MANUAL. TWO OF 3 LNDG GEAR LEGS WERE EXTDD, BUT THE PLTS WERE UNABLE TO EXTD THE LEFT MAIN LNDG GEAR. SUBSEQENTLY, THE ACFT WAS DMGD DRG LNDG. THE HYDR LINE WAS CURVED & MEASURED ABT 15' FM END TO END. IT HAD FAILED AT THE BASE OF A FLARED FITTING. THIS ALLOWED HYDR FLUID IN THE MAIN SYS RESERVOIR TO BE PUMPED OVERBOARD. THE EMERG HYDR SYS HAD A 3 PSN SLCTR: NORMAL, FLAPS DOWN, GEAR DOWN. TESTS OF THE GEAR EXTN SYS REVEALED IT WORKED PROPERLY PER INSTRNS FM THE EMERG CHECKLIST, BUT WITH THE SLCTR IN THE NORMAL PSN, THE LINE FAILURE ALLOWED FLUID TO BE PUMPED FM THE EMERG RESERVOIR TO THE MAIN SYS. A METALLURGICAL EXAM REVEALED THE HYDR LINE HAD FAILED FM MULTIPLE FATIGUE ORIGINS ON THE OUTSIDE DIAMETER OF THE TUBE & ON DIAMETRICALLY OPPOSITE SIDES. LATER, BRITISH AEROSPACE ISSUED A SVC BULLETIN (23-JM-8170) TO REINFORCE THE HYDR LINE.

Probable cause

FAILURE OF THE PILOT(S) TO FOLLOW THE CORRECT EMERGENCY PROCEDURE. FACTORS RELATED TO THIS ACCIDENT WERE: INADEQUATE SYSTEM DESIGN BY THE MANUFACTURER, WHICH ALLOWED HYDRAULIC LINE VIBRATION, FATIGUE FAILURE OF THE LINE, AND LOSS OF FLUID FROM THE NORMAL HYDRAULIC SYSTEM. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
BKN
Ceiling (ft)
25000
Visibility (sm)
10
Wind direction
70
Wind speed (kt)
6
Nearest airport
LAMBERT-ST LOUIS INTL
Distance from field
0.0
Airport elevation
605

Aircraft

RegistrationMakeModelDamageFAR part
N339TE BRITISH AEROSPACE 3201 SUBS 135

Sequence of events

#OccurrencePhase
1 130 Cruise
2 196 Cruise

Findings

Finding
12105 factor
17003 factor
10426
82100 factor
24545 cause