N9808S Adams A55S accident

NTSB ATL99LA103 · 1999-07-04 · WOODSTOCK, GA

Docket — crew, injuries and powerplant

Summary

The pilot reported that the balloon was carefully examined and assembled prior to flight and no mechanical problems were found. After 45 minutes of standing and ascending tether operations, the pilot's son noticed fire dripping from the fitting that connects the main fuel line to the burner assembly. After unsuccessfully trying to extinguish the fire, the pilot pushed his son from the balloon at ground level. The balloon then ascended rapidly to the extent of the 25 foot tethers. At that point, the pilot elected to jump from the balloon. After 15 to 20 minutes, the fire burned through the tether ropes releasing the balloon, which drifted unmanned for approximately one hour before descending and colliding with a single family dwelling. The balloon was destroyed. Examination of the fuel line fitting revealed a loose connection between the two threaded ends. According to the manufacturer of the fuel hose, it is produced for use in air conditioning applications and should never be used with LP gas.

Full narrative

On July 3, 1999, at 2129 eastern daylight time, an unmanned Adams A55S Balloon, N9808S, caught fire, drifted, and collided into a single family dwelling near Woodstock, Georgia. The personal flight was operated by the pilot under provisions of Title 14 CFR Part 91, and visual flight rules. Visual meteorological conditions prevailed at the time of the accident and no flight plan was filed. The commercial pilot was seriously injured and a passenger received minor injuries. The balloon was destroyed. The flight departed Alpharetta, Georgia, at 2000.

According to the pilot, the balloon was picked up from a repair station earlier in the day and taken to a private residence where his instructor and another pilot could examine it. The pilot reported that the balloon was closely examined and carefully assembled. No mechanical problems were reported to have been found and inflation of the balloon was normal. A tether operation of standing and ascending to the extent of the 25 foot tether was conducted for about 45 minutes. The pilot reported that his son noticed fire dripping from the fitting that connects the main fuel line to the burner assembly. The pilot tried unsuccessfully to extinguish the fire with a glove while turning off the two fuel tanks. The pilot pushed his son from the balloon after the fire grew worse and the reduction of weight caused the balloon to ascend rapidly to the extent of the tethers. At this point, the pilot jumped from the balloon and fell 25 feet to the ground. The balloon remained tethered for about 15 to 20 minutes until the fire burned through the tether ropes. After breaking free from the tethers, the balloon ascended and drifted unmanned for about an hour before descending and colliding with a single family dwelling approximately 30 miles from the point of origin.

Damages to the balloon included fire damage to the lower panels, burner assembly, hoses, and uprights. Examination of the fuel line fitting revealed a loose connection between the two threaded ends. According to the manufacturer of the fuel hose, it is produced for use in air conditioning applications and should never be used with LP gas.

Probable cause

A loose connection between the fuel line fitting and the burner assembly which resulted in a fire. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Serious
Weather conditions
Visual Meteorological Cond
Light condition
Dusk
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
9
Wind direction
360
Temperature (F)
70
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N9808S Adams A55S DEST 091

Sequence of events

#OccurrencePhase
1 171 Cruise
2 250 Cruise
3 220 Cruise

Findings

Finding
15103 cause
24102 cause
20200