G0B0B Hawker Siddeley HS.125-35 accident

NTSB BFO90MA023 · 1990-01-31 · COLUMBIA, MO · near COU

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT WAS EN ROUTE AT 31,000 FT, WHEN THE LOW PRESSURE FUEL FILTER WARNING LIGHT ILLUMINATED. THE PLT DIVERTED TOWARD COLUMBIA, MO, BUT BEFORE REACHING COLUMBIA, BOTH ENGINES LOST POWER. SUBSEQUENTLY, THE ACFT CRASHED ABOUT 2 MI EAST OF THE ARPT. AN INVESTIGATION REVEALED THE FUEL WAS CONTAMINATED WITH WATER. THE FUEL FILTER DEICING SYSTEM WAS OPERATIONAL, BUT A POST-ACDNT EXAM REVEALED THE DEICING TANK WAS EMPTY. THIS WAS THE 2ND FLT SINCE THE DEICE TANK HAD BEEN SERVICED. THE MANUFACTURER'S INFO INDICATED THE SUPPLY TANK SHOULD HAVE PROVIDED ABOUT 3 TO 4 HRS OF FILTER DEICING OPERATION.

Probable cause

INADEQUATE PREFLIGHT BY THE PILOT(S), WATER CONTAMINATION OF THE FUEL, LOW LEVEL OF DEICE FLUID (METHANOL) IN THE DEICE TANK, AND SUBSEQUENT ICE BLOCKAGE OF THE FUEL FILTERS. DARKNESS WAS A RELATED FACTOR. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Visual Meteorological Cond
Light condition
Night/Dark
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
60
Wind speed (kt)
8
Temperature (F)
30
Nearest airport
COLUMBIA REGIONAL
Distance from field
0.0
Airport elevation
889

Aircraft

RegistrationMakeModelDamageFAR part
G0B0B Hawker Siddeley HS.125-35 DEST 091F

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 230 Cruise
4 310 Cruise

Findings

Finding
16906
17001 cause
17006 cause
15105 cause
17001 cause
24002 cause
20100 factor
19200
20200