N802X British Aerospace HS125-800 accident

NTSB FTW90IA086 · 1990-03-22 · ATLANTA, GA

Docket — crew, injuries and powerplant

Factual narrative

THE CORPORATE JET WAS CRUISING AT FL330 WHEN THE PILOT NOTED THAT THE AILERONS WERE LOCKED. HE FOUND THAT THE AFT LAVATORY WATER SYSTEM HAD LEAKED TWO AND A HALF GALLONS OF POTABLE WATER INTO THE KEEL AREA OF THE FUSELAGE AROUND THE AILERON CABLES AND PULLEYS. THE PILOT SURMISED THAT THE WATER WAS FROZEN AROUND THE CABLES AND DECLARED AN EMERGENCY. THE OUTSIDE AIR TEMPERATURE WAS -50 C. DURING FINAL APPROACH, AILERON CONTROL WAS REGAINED AND A NORMAL LANDING WAS ACCOMPLISHED. EXAMINATION OF THE LAVATORY WATER SYSTEM REVEALED A CRACKED COPPER OUTPUT LINE ON THE WATER HEATER UNIT.

Probable cause

THE LEAKING AFT LAVATORY WATER HEATER UNIT. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
25
Wind direction
190
Wind speed (kt)
7
Temperature (F)
63
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N802X BRITISH AEROSPACE HS125-800 — 091F

Sequence of events

#OccurrencePhase
1 130 Cruise
2 180 Cruise

Findings

Finding
17105 cause
10729