N9856E Schweizer SGS-1-26B accident

NTSB NYC90LA092 · 1990-04-26 · UNIONVILLE, PA

Docket — crew, injuries and powerplant

Factual narrative

WHILE MAINTAINING AN ALTITUDE OF 1500 FEET, LIGHT RAIN WAS ENCOUNTERED AND THE GLIDER BEGAN LOSING LIFT. A DECISION WAS MADE TO LAND IN THE VALLEY THAT PARALLELED THE GLIDERPORT. DURING ROLL OUT AFTER TOUCHDOWN, THE GROUND DROPPED CAUSING THE GLIDER TO BECOME AIRBORNE AGAIN, AND ANOTHER LANDING WAS ATTEMPTED IN ANOTHER FIELD. HOWEVER, THE GLIDER STRUCK SOME TREES AND WAS DAMAGED.

Probable cause

THE LOSS OF THERMAL LIFT WHICH NECESSITATED A FORCED LANDING ON UNSUITABLE TERRAIN COVERED BY TREES AND HIGH OBSTRUCTIONS. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
300
Wind speed (kt)
10
Temperature (F)
81
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N9856E SCHWEIZER SGS-1-26B SUBS 091

Sequence of events

#OccurrencePhase
1 240 Cruise
2 180 Cruise
3 220 Cruise

Findings

Finding
20000 factor
20000 cause
19200 cause
19200 factor
20200
24542