N8250R Bellanca 17-30A accident

NTSB FTW88LA054 · 1988-01-25 · BORGER, TX · near BGD

Docket — crew, injuries and powerplant

Factual narrative

SHORTLY AFTER TAKEOFF THERE WAS SMOKE IN THE CABIN. THE PLT STARTED A TURN BACK TOWARD THE RUNWAY. WHEN HE TURNED OFF THE ELECTRICAL MASTER SWITCH THE ENGINE STOPPED PRODUCING POWER. ATTEMPTS TO RESTART THE ENGINE WERE NOT SUCCESSFUL. HE IMPACTED A HEAVY CABLE DURING THE OFF-AIRPORT, FORCED LANDING. POST-CRASH INVESTIGATION REVEALED A BROKEN WELD AT THE REAR OF THE LEFT MUFFLER. HEAT FROM THE LEFT MUFFLER MELTED THE INSULATION ON THE 'P' LEADS TO THE MAGNETOS, GROUNDED THEM, AND SHUT OFF THE ENGINE.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
270
Wind speed (kt)
10
Temperature (F)
50
Nearest airport
HUTCHINSON COUNTY
Distance from field
0.0
Airport elevation
3054

Aircraft

RegistrationMakeModelDamageFAR part
N8250R BELLANCA 17-30A SUBS 091

Sequence of events

#OccurrencePhase
1 171 Cruise
2 350 Cruise
3 180 Cruise
4 220 Cruise

Findings

Finding
14402 cause
14813 cause
14813 cause
20200 factor