N74236 Grumman AA-5B accident

NTSB LAX88FA118 · 1988-02-27 · FRAZIER PARK, CA

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT ENG LOST POWER WHILE THE PLT WAS MANEUVERING IN MOUNTAINOUS TERRAIN IN MARGINAL WEATHER AND THE ACFT COLLIDED WITH TREES AND TERRAIN. THE PLT RECEIVED A PREFLT WX BRIEFING DETAILING MOUNTAIN OBSCURATION AND VFR WAS NOT RECOMMENDED. DURING THE FLT PRIOR TO THE ACCIDENT, THE ACFT EXPERIENCED A CARBURETOR FIRE. REVIEW OF MAINTENANCE RECORDS REVEALED THAT PROPER PROCEDURES IN ACCORDANCE WITH THE MANUFACTURERS MAINTENANCE MANUAL WERE NOT FOLLOWED. POST ACCIDENT EXAM OF CARBURETOR REVEALED THAT THE ACCELERATOR PUMP PLUNGER RETAINER WASHER WAS WORN AND HAD SLIPPED OFF THE PLUNGER SEAT. EVIDENCE OF BACKFIRING WAS FOUND IN THE CARBURETOR AIR BOX, AIR FILTER AND VENTURI. THE AIR BOX WAS CLEANED AND AIR FILTER WAS REPORTEDLY REPLACED PREVIOUS TO THE ACCIDENT FLT.

Probable cause

IMPROPER MAINTENANCE PERFORMED PREVIOUS TO THE ACCIDENT FLIGHT WHICH FAILED TO IDENTIFY A FAULT WHICH RENDERED THE AIRPLANE NONAIRWORTHY. CONTRIBUTING TO THIS ACCIDENT WAS THE PILOT'S EXERCISE OF POOR JUDGEMENT IN DISREGARDING WEATHER FORECASTS INDICATING WEATHER WAS BELOW MINIMUMS. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
BKN
Ceiling (ft)
10000
Visibility (sm)
7
Wind direction
150
Wind speed (kt)
10
Temperature (F)
64
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N74236 GRUMMAN AA-5B DEST 091

Sequence of events

#OccurrencePhase
1 240 Cruise
2 350 Cruise
3 180 Cruise
4 230 Cruise

Findings

Finding
20000 factor
24023 factor
24022 factor
15109 cause
24102 cause
20200