N157UA Boeing 747-123 accident

NTSB DCA88IA056 · 1988-05-02 · NR TOKYO, PO · near NRT

Docket — crew, injuries and powerplant

Factual narrative

UNITED FLT 97 EXPERIENCED INDICATIONS OF UNEVEN FUEL FLOW FROM MAIN TANKS 2 AND 3 AT FL360 BEGINNING ABOUT 4- HOURS AFTER DEPARTURE ON AN 11-HOUR TRANSPACIFIC FLIGHT. THE FUEL SYSTEM HAD BEEN SET UP FOR ALL ENGINE FEED FROM THE NOS 2 AND 3 TANKS. ALTHOUGH IT WAS LATER ESTABLISHED THAT THE NUMBER 2 CROSSFEED VALVE FAILED IN THE CLOSED POSITION, THE S/O INFORMED THE CAPT THAT THE INTRANSIT LIGHT HAD ILLUMINATED WHEN THE VALVE SELECTOR WAS MOVED TO THE CLOSED POSITION - INDICATING NORMAL CROSSFEED VALVE OPERATION. FUEL SYSTEM PROBLEM WAS MISDIAGNOSED AS A PROBLEM OF FAULTY FUEL GAGE INDICATIONS. FUEL MONITORING INDICATED INSUFFICIENT FUEL FLOW FROM NO 2 TANK WHEN CROSSFEEDING. ENGS 1, 3, AND 4 FLAMED OUT WHEN FUEL WAS EXPENDED FROM ALL TANKS EXCEPT NO 2. EMERGENCY DESCENT WAS MADE TO DESTINATION TOKYO-NARITA AIRPORT. CREW REPORTED THEY USED FLAPS-20, BUT DFDR SHOWED FLAPS-1 WAS USED FOR LANDING. 3 TIRES BLEW ON LANDING. ALL 3 FLIGHTCREW QUALIFIED IN THE B-747 IN THE 13-MONTHS BEFORE THE INCIDENT.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
UNK
Ceiling (ft)
0
Visibility (sm)
5
Wind direction
0
Nearest airport
TOKYO-NARITA
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N157UA BOEING 747-123 MINR 121

Sequence of events

#OccurrencePhase
1 130 Cruise
2 353 Cruise
3 200 Cruise

Findings

Finding
15100 factor
15132 factor
16907
17001 cause
22200 cause
24032 cause
24621
24624 factor
34310 factor
34333 factor
22111 factor