N710AA Boeing 727-200 accident

NTSB FTW88IA165 · 1988-09-22 · DFW AIRPORT, TX · near DFW

Docket — crew, injuries and powerplant

Factual narrative

ACFT RECEIVED MINOR DAMAGE WHEN THE PLT EXECUTED AN EMERGENCY GEAR UP LANDING FOLLOWING THE FAILURE OF THE MLG TO EXTEND USING NORMAL, ABNORMAL, AND MANUAL PROCEDURES. ACFT WAS LANDED WITH THE NLG EXTENDED AND THE MAINS RETRACTED. INVESTIGATION REVEALED THAT THE LEFT MLG DOOR ACTUATOR PIVOT TRUNNION UPPER SHAFT HAD FAILED AS A RESULT OF A FATIGUE FRACTURE. FOLLOWING THE FRACTURE, THE SEPARATED SHAFT HAD BECOME JAMMED BETWEEN THE TRUNNION AND THE ACTUATOR CLEVIS WHICH PREVENTED THE MANUAL DOOR UNLOCK MECHANISM FROM RELEASING. A REVIEW OF THE SERVICE DIFFICULTY HISTORY OF THE FAILED PART INDICATED THAT SEVERAL SIMILAR FAILURES HAD OCCURRED ON MANUFACTURED PARTS AND THAT A REDESIGNED PART WAS AVAILABLE FOR REPLACEMENT. THE OPERATOR HAD COMPLIED WITH ALL OF THE REQUIRED INSP'S.

Probable cause

FATIGUE FAILURE OF THE LEFT MAIN LANDING GEAR DOOR ACTUATOR PIVOT TRUNNION SHAFT WHICH SUBSEQUENTLY BECAME LODGED IN THE ACTUATOR CLEVIS PREVENTING THE DOOR UNLOCK MECHANISM FROM ACTUATING DURING GEAR EXTENSION. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Incident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Night/Bright
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
170
Wind speed (kt)
8
Temperature (F)
84
Nearest airport
DFW REG.
Distance from field
0.0
Airport elevation
603

Aircraft

RegistrationMakeModelDamageFAR part
N710AA BOEING 727-200 MINR 121

Sequence of events

#OccurrencePhase
1 130 Cruise
2 230 Cruise

Findings

Finding
10426 cause
10426 cause
10426
10407
82100 cause
24556