N8226P Piper PA-24-250 accident

NTSB MIA89LA045 · 1988-11-28 · CRESTVIEW, FL · near CEW

Docket — crew, injuries and powerplant

Factual narrative

WHILE IN CRUISE FLT NEAR AN ARPT, THE PROP SEPARATED. PLT WAS GIVEN VECTORS TO ARPT & ENTERED PATTERN FOR LNDG. DOWNWIND LEG WAS EXTENDED DUE TO STRONG TAILWIND. STRONG HEADWIND ON FINAL CAUSED ACFT TO LAND SHORT. DURING LANDING ROLL ACFT COLLIDED WITH TWO FENCES. EXAMINATION OF ACFT REVEALED 6 PROP MOUNT BOLTS FAILED DUE TO FATIGUE AS A RESULT OF IMPROPER PLACEMENT OF PROP MOUNTING SHIM BETWEEN ENGINE CRANKSHAFT FLANGE AND STARTER GEAR FLANGE. ACFT MANUAL STATED PROP MOUNT BOLTS MAY FAIL DUE TO RELATIVE MOVEMENT BETWEEN THE TWO FLANGES IF SHIM IS NOT INSTALLED. CORRECT PLACEMENT OF THE SHIM IS BETWEEN THE PROP FLANGE & THE STARTER GEAR FLANGE. SUDDEN ENG STOPPAGE APROX 45 HRS EARLIER RESULTED IN PROP REMOVAL, OVERHAUL, & REINSTALLATION.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Night/Dark
Sky condition
BKN
Ceiling (ft)
8000
Visibility (sm)
10
Wind direction
330
Wind speed (kt)
10
Temperature (F)
54
Nearest airport
BOB SIKES
Distance from field
0.0
Airport elevation
215

Aircraft

RegistrationMakeModelDamageFAR part
N8226P PIPER PA-24-250 SUBS 091

Sequence of events

#OccurrencePhase
1 130 Cruise
2 180 Cruise
3 390 Cruise
4 310 Cruise

Findings

Finding
14500 cause
14500 cause
24111 cause
20100 factor
20000 factor
24022 factor
20200
20200