N94EC Eller BD-5B accident

NTSB DEN89LA080 · 1989-02-24 · COLORADO SPRING, CO · near COS

Docket — crew, injuries and powerplant

Factual narrative

THE COMMERCIAL PLT WAS PERFORMING AN INITIAL FLIGHT ON HIS SINGLE PLACE HOMEBUILT ACFT. DURING INITIAL CLIMB, AT 400 FT AGL, THE GEAR AND FLAPS WERE RETRACTED. 10 SECONDS LATER THE ENGINE SEEMED TO LOSE POWER AND THE PLT SWITCHED FUEL TANKS. THE POWER RESUMED AND 20 SECONDS LATER THE PLT SAID THE ENGINE STOPPED. THE PLT MADE A 180 DEG TURN AND ATTEMPTED TO RETURN TO THE AIRPORT. THE PLANE UNDERSHOT AND LANDED 100 FEET SHORT OF THE RWY. THE PLT REPORTED THE LANDING GEAR PINCHED THE FLEXIBLE FUEL LINES WHEN RETRACTED. AN FAA INSPECTOR CONCURRED AFTER A POST ACCIDENT INSPECTION. 5 WEEKS LATER THE PLT WROTE A LETTER STATING THAT HE FELT THAT WATER IN THE AUTO FUEL CAUSED THE REPORTED ENGINE STOPPAGE.

Probable cause

THE IMPROPER INSTALLATION OF FUEL LINES WHICH WERE PINCHED OFF CAUSING FUEL STARVATION WHEN THE GEAR WAS RETRACTED. A FACTOR IN THE ACCIDENT WERE THE TERRAIN FEATURES INCLUDING LOOSE GRAVEL SHORT OF THE RUNWAY. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
50
Wind direction
120
Wind speed (kt)
3
Temperature (F)
50
Nearest airport
COLORADO SPRINGS
Distance from field
0.0
Airport elevation
6172

Aircraft

RegistrationMakeModelDamageFAR part
N94EC ELLER BD-5B SUBS 091

Sequence of events

#OccurrencePhase
1 350 Cruise
2 180 Cruise
3 230 Cruise

Findings

Finding
15102
17001
24111 cause
22002
19200 factor