N7025L Mbb BK-117 A-1 accident

NTSB FTW89FA049 · 1989-02-14 · TYLER, TX

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT CRASHED AFTER CONTACTING 70' TALL HIGH TENSION POWER LINES WHILE ON A NIGHT NON-EMERGENCY EMS MISSION. ACCORDING TO WITNESSES, WX WAS IMC WITH LOW OVC CEILINGS, 1/4 TO 1 MILE VIS WITH RAIN AND FOG AND THUNDERSTORMS THROUGHOUT THE AREA. WITNESSES STATED THE RAIN VARIED FROM DRIZZLE TO VERY HEAVY. THE PILOT RECEIVED 3 BRIEFINGS FROM AFSS AND WAS FULLY AWARE OF THE CONDITIONS. HE HAD THE AUTHORITY TO REFUSE THE MISSION IF, IN HIS JUDGEMENT, THE WX WAS QUESTIONABLE OR UNACCEPTABLE. THE HOSPITAL HAD WRITTEN PROCEDURES FOR INADVERTENT FLIGHT INTO IMC WHICH THE PLT DID NOT FOLLOW. RECORDS FAIL TO INDICATE THAT THE PILOT HAD REVIEWED THESE PROCEDURES NOR DO THEY INDICATE THAT THE PILOT HAD RECEIVED ANY IFR TRAINING DURING HIS 1 MONTH EMPLOYMENT.

Probable cause

THE PILOT'S FAILURE TO EXECUTE THE PUBLISHED INADVERTENT IMC PROCEDURES WHEN HE ENCOUNTERED ADVERSE WEATHER CONDITIONS. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Instrument Meteorological Cond
Light condition
Night/Dark
Sky condition
OVC
Ceiling (ft)
1200
Visibility (sm)
1
Wind direction
330
Wind speed (kt)
12
Temperature (F)
61
Distance from field
0.0
Airport elevation
544

Aircraft

RegistrationMakeModelDamageFAR part
N7025L MBB BK-117 A-1 DEST 135

Sequence of events

#OccurrencePhase
1 240 Cruise
2 220 Cruise
3 250 Cruise
4 230 Cruise

Findings

Finding
20000
20000
20000
20100
24023 factor
24545 cause
34210 factor
34240 factor
20200 factor
24526 cause