N1365F Cessna 172G accident

NTSB ATL89LA102 · 1989-03-11 · COOLIDGE, GA

Docket — crew, injuries and powerplant

Factual narrative

THE ENGINE LOST PWR DURING A FERRY FLT & A FORCED LDG WAS MADE IN A SOFT FIELD, WHERE THE AIRPLANE NOSED OVER. A POST-CRASH INVESTIGATION REVEALED THAT THE CARBURETOR FUEL-INLET FILTER SCREEN WAS MOSTLY BLOCKED WITH A LINT-LIKE MATERIAL. A MICROSCOPIC EXAM OF THE MATERIAL REVEALED THAT IT APPEARED TO BE CLOTH FIBERS. THE SOURCE OF THE MATERIAL WAS NOT DETERMINED. FURTHER INVESTIGATION REVEALED THAT THE ENGINE HAD EXPERIENCED REPEATED, INTERMITTENT PWR LOSSES OVER THE PREVIOUS WEEK IN SPITE OF REPEATED EFFORTS BY COMPANY MECHANICS TO LOCATE THE SOURCE OF THE PROBLEM. ACCORDING TO THE MECHANICS, CONTAMINATION WAS FOUND IN THE FUEL SYSTEM DURING THOSE EFFORTS; THE FILTERS WERE CLEANED AND THE FUEL SYSTEM WAS FLUSHED. THE INTERMITTENT POWER LOSSES OCCURRED AGAIN. EARLIER ON THIS FLT, THE ENGINE BEGAN TO SURGE & A PRECAUTIONARY LDG WAS MADE. THE MECHANIC ACCOMPANYING THE PLT REPORTEDLY FOUND NO PROBLEMS AND THE FLT WAS CONTINUED. THE ACCIDENT OCCURRED ABOUT 1 HR LATER.

Probable cause

FUEL CONTAMINATION OF AN UNKNOWN ORIGIN, FAILURE OF COMPANY MAINTENANCE PERSONNEL TO LOCATE AND REMOVE ALL CONTAMINATION, CONTINUED OPERATION OF THE AIRCRAFT BY THE PILOT AFTER THE CAUSE OF A KNOWN ENGINE PROBLEM WAS NOT DETERMINED, AND SUBSEQUENT FUEL STARVATION. THE LIGHT CONDITIONS AT DUSK AND THE SOFT TERRAIN IN THE EMERGENCY LANDING AREA WERE CONTRIBUTING FACTORS. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Dusk
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
3
Wind direction
0
Temperature (F)
61
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N1365F CESSNA 172G SUBS 091

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 300 Cruise

Findings

Finding
17001 cause
17001 cause
24102 cause
24007 cause
20100 factor
19200 factor