N52634 Cessna 177RG accident
NTSB CHI89FA058 · 1989-03-18 · ROCKFORD, IL · near RFD
Docket — crew, injuries and powerplant
Factual narrative
THE MAIN LANDING GEAR COLLAPSED DURING THE ROLLOUT OF A FULL STOP LANDING. THE HYDRAULIC POWER PACK UNIT HAD BEEN REPLACED RECENTLY. THIS WAS ONLY THE SECOND FLIGHT AND SECOND LANDING SINCE THE REPLACEMENT OF THE UNIT. THE HYDRAULIC RESERVOIR WAS SLIGHTLY LESS THAN HALF FULL. GEAR OPERATION COULD NOT BE OBTAINED IN A FUNCTIONAL TEST WITH THE HYDRAULICFLUID LEVEL EXISTENT IN RESERVOIR. NORMAL GEAR FUNCTION WAS OBTAINED AFTER RESERVOIR WAS SERVICED TO OPERATING CAPACITY.
Probable cause
THE INADEQUATE SERVICING OF THE HYDRAULIC FLUID BY MAINTENANCE PERSONNEL AND THE PILOT'S FAILURE TO EXTEND THE LANDING GEAR MANUALLY. The National Transportation Safety Board determined the probable cause of this accident.
Circumstances
- Event type
- Accident
- Highest injury
- None
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- BKN
- Ceiling (ft)
- 25000
- Visibility (sm)
- 8
- Wind direction
- 300
- Wind speed (kt)
- 12
- Temperature (F)
- 27
- Nearest airport
- GREATER ROCKFORD
- Distance from field
- 0.0
- Airport elevation
- 736
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N52634 | CESSNA | 177RG | SUBS | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | 191 | Cruise |
Findings
| Finding | |
|---|---|
| 12104 | factor |
| 12102 | factor |
| 22003 | |
| 24111 | cause |
| 24101 | cause |
| 24545 | cause |