N85DP Piccard AX-6 accident

NTSB FTW89FA136 · 1989-07-16 · HOUSTON, TX

Docket — crew, injuries and powerplant

Factual narrative

THE BALLOON FAILED TO ESTABLISH A CLIMB AND CLEAR A SET OF POWER LINES DESPITE THE FACT THAT, ACCORDING TO WITNESSES, THE PILOT ACTUATED THE BURNER REPEATEDLY. WHEN IT STRUCK POWER LINES, A TANK EXPLODED, AND THE BASKET WAS RELEASED AND CONSUMED BY FIRE. INVESTIGATION REVEALED THAT THE DEFLATION SYSTEM HAD NOT BEEN ACTIVATED PRIOR TO THE WIRE STRIKE. ALSO, THE ENVELOPE WAS IN POOR REPAIR, WHICH DECREASED ITS EFFFICIENCY. THE PRIVATE BALLOON PILOT HAD ACCUMULATED A TOTAL OF 9 HOURS AS PIC OUT OF A TOTAL OF 24.

Probable cause

THE PILOT'S FAILURE TO ABORT THE ATTEMPT TO CLEAR THE OBSTACLE. FACTORS IN THE ACCIDENT WERE: THE POOR CONDITION OF THE BALLOON ENVELOPE AND THE PILOT'S LACK OF EXPERIENCE AS PILOT IN COMMAND OF BALLOON OPERATIONS. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
250
Wind speed (kt)
3
Temperature (F)
84
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N85DP PICCARD AX-6 DEST 091

Sequence of events

#OccurrencePhase
1 220 Cruise
2 170 Cruise

Findings

Finding
20200
24526 cause
24545 cause
24116 factor
34335 factor
15101 cause