N27113 Balloon Works FIREFLY 6B accident

NTSB FTW89FA143 · 1989-08-05 · BATON ROUGE, LA

Docket — crew, injuries and powerplant

Factual narrative

THE PLT WAS PARTICIPATING IN THE U.S. NATIONAL HOT AIR BALLOON CHAMPIONSHIP. VIDEO TAPES SHOWED THAT AT AN UNDETERMINED ALT AFTER TAKEOFF, THE BALLOON'S RATE OF ASCENT INCREASED SUBSTANTIALLY. SUBSEQUENTLY, AT ABOUT 3000 FT AGL, FABRIC WAS OBSERVED TO BEGIN FLAPPING & THE BALLOON ENTERED A RAPID DESCENT WITH THE BURNER OPERATING. IT THEN IMPACTED IN AN UNCONTROLLED DESCENT. AN EXAM OF THE BALLOON REVEALED EVIDENCE OF OVERHEATING OF THE FABRIC. THERE WAS EVIDENCE THAT OVERHEATING HAD OCCURRED OVER A LONG PERIOD OF TIME. THE REQUIRED TEMP GAGE, WHICH SHOULD HAVE BEEN MOUNTED IN THE TOP OF THE GONDOLA, WAS NOT FOUND.

Probable cause

THE PILOT EXCEEDED THE TEMPERATURE LIMITATIONS OF THE BALLOON DURING THE CLIMB, WHICH RESULTED IN FAILURE OF THE FRABRIC. FACTORS RELATED TO THE ACCIDENT WERE: THE PREVIOUS HEAT DAMAGE TO THE FRABRIC, AND THE LACK OF MAINTENANCE BY THE PILOT/OWNER. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
280
Wind speed (kt)
5
Temperature (F)
95
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N27113 Balloon Works FIREFLY 6B SUBS 091

Sequence of events

#OccurrencePhase
1 130 Cruise
2 230 Cruise

Findings

Finding
17601 factor
17601 cause
24100 factor
24538 cause