N699T Beech V35B accident

NTSB MKC89LA187 · 1989-08-18 · CONCORD, AR

Docket — crew, injuries and powerplant

Factual narrative

THE PILOT/OWNER SAID THAT WHILE CLIMBING THROUGH 9000 FT MSL FOR 10,000 FT MSL, ON AN IFR FLIGHT PLAN, HE SMELLED AN ELECTRICAL ODOR. THE CABIN BEGAN TO FILL WITH DENSE SMOKE, SO HE SHUT OFF ALL ELECTRICAL SWITCHES. AN EMERGENCY DESCENT WAS MADE. DURING THE DESCENT, THE SMOKE WAS SUBSTANTIALLY CLEARED FROM THE CABIN. THE LANDING GEAR WAS EXTENDED BY USING EMERGENCY PROCEDURES. WHILE LANDING ON ROLLING TERRAIN, THE GEAR COLLAPSED & THE ACFT WAS DAMAGED. THERE WAS NO CONTINUATION OF FIRE ON THE GROUND. A POST-ACDNT INVESTIGATION REVEALED THE OWNER HAD IMPROPERLY INSTALLED AN ALTERNATOR WIRING HARNESS, WHICH RUBBED ON THE NOISE SUPPRESSOR. AFTER IT RUBBED THRU THE INSULATION, AN ELECTRICAL FIRE ERUPTED.

Probable cause

IMPROPER INSTALLATION OF THE ALTERNATOR WIRING HARNESS BY THE PILOT/OWNER WHICH RESULTED IN CHAFED WIRING AND A SUBSEQUENT ELECTRICAL FIRE. THE UNEVEN TERRAIN WAS A CONTRIBUTING FACTOR. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
BKN
Ceiling (ft)
8000
Visibility (sm)
5
Wind direction
210
Wind speed (kt)
5
Temperature (F)
90
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N699T BEECH V35B SUBS 091

Sequence of events

#OccurrencePhase
1 171 Cruise
2 180 Cruise
3 230 Cruise
4 190 Cruise

Findings

Finding
12013 cause
12013 cause
24111 cause
19200 factor
10400