N9465W Piper PA-28-235 accident

NTSB CHI90FA029 · 1989-11-22 · MONROE CENTER, IL

Docket — crew, injuries and powerplant

Factual narrative

NON-INSTRUMENT RATED PRIVATE PILOT TOOK OFF IN IMC CONDITIONS AT NIGHT; CRASHED 9 MINUTES LATER. WITNESSES REPORTED SEEING THE AIRCRAFT IN A STEEP DIVE, ON FIRE, PRIOR TO IMPACT. EXTENSIVE FIRE DAMAGE INTERIOR CABIN. NO EVIDENCE OF INSULATION GROMMET AT FRAME PENETRATION OF MAIN WIRING HARNESS, OR CABLE INSULATION FROM THIS POINT TO BATTERY. BATTERY BOX BULGED OUT ALL SIDES, BLACK & CHARRED. WING SPAR WEB MELTED AND MISSING FROM WHERE ELECT FUEL PUMP ATTACHES TO SPAR TO RIGHT SIDE WING ATTACH POINT. ALUM WIRING REPLACED DURING LAST ANNUAL 4/29/89. LOG SHEET ENTRY 11/18/89 'BAD GAS SMELL!'.

Probable cause

IN-FLIGHT FIRE INITIATED BY AN INADEQUATELY INSTALLED WIRING HARNESS AND PROPAGATED BY AN EXISTING FUEL LEAK WHICH WAS NOT REPAIRED. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Instrument Meteorological Cond
Light condition
Night/Dark
Ceiling (ft)
400
Visibility (sm)
1
Wind direction
70
Wind speed (kt)
6
Temperature (F)
25
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N9465W PIPER PA-28-235 DEST 091

Sequence of events

#OccurrencePhase
1 171 Cruise
2 230 Cruise

Findings

Finding
12013 cause
12013 cause
15124 cause
10003
24111 cause
24102 cause