N2566X Cessna P206 accident

NTSB FTW90LA023 · 1989-11-05 · THELMA, TX

Docket — crew, injuries and powerplant

Factual narrative

ABOUT 10 MINUTES AFTER TAKEOFF, THE PLT SWITCHED FROM THE RIGHT TO THE LEFT FUEL TANK AND THE ENGINE QUIT. HIS RESTART ATTEMPTS WERE UNSUCCESFFUL AND HE SET UP A FORCED LANDING APPROACH TO AN OPEN FIELD. ON FINAL, THE ACFT STRUCK POWER LINES AND SUBSEQUENTLY IMPACTED THE GROUND. INVESTIGATION REVEALED LARGE QUANTITIES OF WATER THROUGHOUT THE FUEL SYSTEM AND ENGINE. THE FUEL CAPS WERE OF THE PROPER KIND AND IN GOOD CONDITION. THE PLT STATED THAT THE ACFT HAD BEEN TOPPED OFF 6 DAYS PRIOR TO THE ACCIDENT AND THAT HE SUMPED THE TANKS PRIOR TO TAKEOFF. IT WAS DETERMINED THAT THE ACFT HAD FLOWN AT LEAST ONCE AFTER THE LAST REFUELING. THE ACFT HAD BEEN TIED DOWN OUTSIDE AT AN AIRPORT THAT HAD RECEIVED 5 INCHES OF RAIN DURING THE WEEK PRECEDING THE ACCIDENT.

Probable cause

THE PILOT'S FAILURE TO DRAIN ALL THE WATER FROM THE FUEL SYSTEM DURING PREFLIGHT. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Serious
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
OVC
Ceiling (ft)
8000
Visibility (sm)
10
Wind direction
180
Wind speed (kt)
12
Temperature (F)
79
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N2566X CESSNA P206 SUBS 091

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 220 Cruise
4 230 Cruise

Findings

Finding
17001 cause
24001 cause
20200