N8286 Hiller UH-12E accident

NTSB DEN87LA146 · 1987-06-09 · GRAFTON, ND

Docket — crew, injuries and powerplant

Factual narrative

THE PLT WAS POSITIONING THE HELICOPTER FOR AN AERIAL APPLICATION PROJECT. BEFORE TAKING OFF, HE CHECKED THE FUEL QUANTITY INDICATOR & ESTIMATED THERE WAS 30 MIN OF FUEL ON BOARD. THE PROPOSED FLT WAS ESTIMATED TO TAKE 10 MIN. DURING FLT, THE ENG LOST POWER & THE PLT MADE AN AUTOROTATION WHICH TERMINATED IN A HARD LANDING. A POST ACDNT EXAM REVEALED THE FUEL TANK WAS EMPTY & THE FUEL GAGE TEST SWITCH WAS DEFECTIVE. RPRTDLY, THE DEFECTIVE SWITCH WOULD RESULT IN AN INACCURATE FUEL QUANTITY INDICATION. NO OTHER PRE-ACDNT FAILURE OR DEFICIENCY WAS FOUND.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
240
Wind speed (kt)
3
Temperature (F)
63
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N8286 HILLER UH-12E SUBS 091

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 200 Cruise

Findings

Finding
15404 factor
17001 cause
24002 cause
22204 cause
24520
24535 factor