N966C Airbus Industrie A-300-B4-203 accident

NTSB DEN87IA207 · 1987-08-03 · DENVER, CO · near DEN

Docket — crew, injuries and powerplant

Factual narrative

AS COPLT ACCELERATED ACFT THROUGH 128 KTS FOR TAKEOFF, ELECTRICAL MALFUNCTION OCCURRED RESULTING IN UNRELIABLE INSTRUMENT INDICATIONS. CAPT REJECTED TAKEOFF. ACFT WENT OFF END OF 12000-FT RWY. POST-INCIDENT EXAMINATION DISCLOSED NO. 1 CONSTANT SPEED DRIVE (CSD) OUTPUT SLOWED DUE TO OIL LEAKAGE. GENERATOR CONTROL UNIT TRIPPED AND OPENED LINE CONTACTOR. WITH REMOVAL OF ELECTRICAL LOAD, CSD OUTPUT SPEED INCREASED & ELECTRICAL LOAD REAPPLIED. CYCLE REPEATED ITSELF EVERY 0.84 SECONDS. CSD HAD NEVER BEEN OVERHAULED IN 10 YRS OF SERVICE. CVR/DFDR REVEALED ELECTRICAL MALFUNCTION OCCURRED AT 1240:12 & ABORT COMMAND GIVEN AT 1240:29. AT 1240:26, WHEN PWR WAS RESTORED TO DFDR, ACFT WAS DECELERATING THRU 171.08 KIAS. V1,VR, & V2 COMPUTED TO BE 161, 161, AND 165 KTS & ACCELERATE-STOP DISTANCE ABOUT 11,500 FT. INVESTIGATION FURTHER REVEALED ACFT GREEN BRAKE SYSTEM INOP & YELLOW SYSTEM USED. ADDITIONALLY, NO. 7 BRAKE ANTISKID INOP. BOTH ARE ALLOWABLE DEFERRED MAINTENANCE ITEMS.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
OVC
Ceiling (ft)
25000
Visibility (sm)
30
Wind direction
10
Wind speed (kt)
11
Temperature (F)
77
Nearest airport
STAPLETON INT'L
Distance from field
0.0
Airport elevation
5333

Aircraft

RegistrationMakeModelDamageFAR part
N966C Airbus Industrie A-300-B4-203 MINR 121

Sequence of events

#OccurrencePhase
1 130 Cruise
2 340 Cruise

Findings

Finding
12006 cause
24121 cause
24502 cause
10419 factor
24503 cause