N3666W Piper PA-32-260 accident

NTSB FTW88FA023 · 1987-11-04 · FULTON, TX · near RKP

Docket — crew, injuries and powerplant

Factual narrative

ACFT DEPARTED IN CONDITIONS OF LOW CEILING AND VISIBILITY WITH A STUDENT PLT AND PAX ON BOARD. WITNESSES AT THE ARPT ESTIMATED THE CEILING AS 150 TO 300 FT OVC WITH 1/8 TO 1/4 MILE VIS IN FOG. AFTER LIFT OFF THE ACFT ENTERED THE FOG IN A RT CLIMBING TURN AND REAPPEARED OVER THE RUNWAY HEADING IN THE OPPOSITE DIRECTION AT VERY LOW ALTITUDE. WITNESSES ON THE BEACH, ABOUT 1/2 MILE FROM THE ARPT STATED THAT THE WEATHER WAS 'POOR AND FOGGY'. THEY OBSERVED THE ACFT IMPACT THE WATER IN A RT BANK AND DISAPPEAR. INVESTIGATION REVEALED THAT THE ENG DRIVEN VACUUM PUMP WAS INOPERATIVE AT THE TIME OF T/O. THE PUMP HAD A SHEARED DRIVE SHAFT THAT EXHIBITED CONSIDERABLE WEAR. IN ADDITION, THE PUMP VANES WERE EXCESSIVELY WORN AND ONE VANE WAS FOUND JAMMED BETWEEN THE ROTOR AND THE CASE. DETAILED EXAMINATION OF THE PUMP REVEALED THAT IT HAD BEEN INOPERATIVE FOR SOME TIME PRIOR TO THE ACCIDENT.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Instrument Meteorological Cond
Light condition
Day
Sky condition
OVC
Ceiling (ft)
300
Wind direction
280
Wind speed (kt)
4
Temperature (F)
73
Nearest airport
ARANSAS COUNTY
Distance from field
0.0
Airport elevation
25

Aircraft

RegistrationMakeModelDamageFAR part
N3666W PIPER PA-32-260 DEST 091

Sequence of events

#OccurrencePhase
1 240 Cruise
2 250 Cruise
3 230 Cruise

Findings

Finding
20000 factor
20000 factor
24001 cause
24405 factor
24022 cause
24015 cause
31160 factor
13102 factor
12205 factor
22100 cause
24115 factor
33400 cause
19200