N4881V Bellanca 17-300 accident

NTSB FTW86LA070 · 1986-04-18 · EL PASO, TX

Docket — crew, injuries and powerplant

Factual narrative

THE ENG QUIT DUE TO FUEL STARVATION. THE ACFT HAD BEEN FLOWN 2.6 HOURS ON THE MAIN TANKS. NORMAL OPERATING TIME ON THE MAIN TANKS IS 2.5 HOURS ACCORDING TO THE OWNER'S MANUAL OF THE BELLANCA VIKING 300 SERIES. AT THE CRASH SITE THE MAIN TANKS WERE FOUND EMPTY AND THE AUX TANKS WERE FULL. THE PLT HAD FAILED TO SWITCH FROM THE MAIN TANKS TO THE AUX TANKS. NO EVIDENCE OF ENG MALFUNCTION WAS FOUND TO EXIT WHEN EXAMINED.

Circumstances

Event type
Accident
Highest injury
Serious
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
50
Wind direction
260
Wind speed (kt)
5
Temperature (F)
73
Distance from field
6.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N4881V BELLANCA 17-300 DEST 091

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 230 Cruise

Findings

Finding
17001 factor
24010 factor
22201 cause