N260A Smith, Ted Aerostar AEROSTAR 600 accident
NTSB ATL86FA147 · 1986-05-29 · DICKSON, TN · near MO2
Docket — crew, injuries and powerplant
Factual narrative
THE ACFT CONTACTED ELECTRICAL WIRES AND TREES SHORTLY AFTER TAKEOFF. THE ACFT THEN DESCENDED TO IMPACT WITH THE TERRAIN. EXAMINATION OF THE WRECKAGE REVEALED THE ELEVATOR TRIM ACTUATOR ROD WAS EXTENDED 2.5 INCHES WHICH CORRELATES WITH A FULL NOSE DOWN SETTING. FURTHER EXAMINATION SHOWED THE BUSS WIRE FOR THE ACTUATOR RETRACT SWITCH WAS DISCONNECTED AT THE RETRACT SWITCH POST. SPLATTERED COPPER WAS FOUND ON THE RETRACT SWITCH INDICATING THE BUSS WIRE HAD BEEN SUBJECTED TO HIGH AMPERAGE. THE LIMITATIONS SECTION OF THE PILOT OPERATING HANDBOOK FOR THIS ACFT DOES NOT STATE THAT TAKEOFF IS PROHIBITED WITH INOPERATIVE PITCH TRIM.
Circumstances
- Event type
- Accident
- Highest injury
- Fatal
- Weather conditions
- Instrument Meteorological Cond
- Light condition
- Night/Dark
- Sky condition
- OVC
- Ceiling (ft)
- 500
- Visibility (sm)
- 4
- Wind direction
- 200
- Wind speed (kt)
- 3
- Temperature (F)
- 66
- Nearest airport
- DICKSON MUNICIPAL
- Distance from field
- 1.0
- Airport elevation
- 891
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N260A | Smith, Ted Aerostar | AEROSTAR 600 | DEST | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | 250 | Cruise |
| 2 | 220 | Cruise |
| 3 | 230 | Cruise |
Findings
| Finding | |
|---|---|
| 20000 | |
| 20000 | |
| 20100 | |
| 10704 | cause |
| 12013 | cause |
| 12013 | cause |
| 22120 | cause |
| 24527 | cause |
| 34130 | factor |
| 20200 | |
| 20200 |