N101MW Rutan VARIEZE accident
NTSB CHI85LA113 · 1985-02-17 · MT. VERNON, IL · near MVN
Docket — crew, injuries and powerplant
Factual narrative
THE ACFT LNDG GEAR COLLAPSED AFTER SEVERAL LNDGS. THE PLT WAS PRACTICING TOUCH & GO LNDGS AND COMPLETED 5 CIRCUITS. DURING THE 6TH LNDG THE MAIN GEAR COLLAPSED AT TOUCHDOWN. THE NOSE GEAR THEN COLLAPSED THIS MODEL VARIEZE WAS EQUIPPED WITH A LNDG GEAR THAT WAS FOUND TO BE TOO WEAK. LATER VERSIONS HAD AN IMPROVED SYSTEM WHICH WAS STRONGER. NO PROVISION TO MAKE THE CHANGE MADATORY HAD BEEN MADE.
Circumstances
- Event type
- Accident
- Highest injury
- None
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- BKN
- Ceiling (ft)
- 20000
- Visibility (sm)
- 7
- Wind direction
- 210
- Wind speed (kt)
- 10
- Temperature (F)
- 43
- Nearest airport
- MT VERNON
- Distance from field
- 0.0
- Airport elevation
- 480
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N101MW | RUTAN | VARIEZE | SUBS | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | 130 | Cruise |
| 2 | 190 | Cruise |
Findings
| Finding | |
|---|---|
| 10402 | cause |
| 10402 | cause |
| 82126 | cause |
| 91400 | cause |