N1ZF Globe SWIFT GC-1B accident
NTSB MIA85FA102 · 1985-02-23 · ROCKLEDGE, FL
Docket — crew, injuries and powerplant
Factual narrative
THE ACFT CRASHED INTO A FIELD AFTER EXPERIENCING A LOSS OF PWR. INSPECTION REVEALED ONE OF THE TWO CHECK VALVES INSIDE THE ENG DRIVEN FUEL PUMP WAS UNSETTED AND WEDGED BETWEEN THE METAL PUMP HOUSING AND THE PUMP DIAPHRAM ACTUATING PLATE. WITH THE CHECK VALVE IN THIS POSITION, NO FUEL FLOW WAS OBSERVED DURING TESTING. WHEN THE CHECK VALVE WAS RESETTED, NORMAL PUMP OPERATION WAS OBSERVED. THE ELECTRIC FUEL PUMP WAS FOUND IN THE 'OFF' POSITION.
Circumstances
- Event type
- Accident
- Highest injury
- Fatal
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- NONE
- Ceiling (ft)
- 0
- Visibility (sm)
- 7
- Wind direction
- 110
- Wind speed (kt)
- 8
- Temperature (F)
- 73
- Distance from field
- 0.0
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N1ZF | GLOBE | SWIFT GC-1B | SUBS | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | 351 | Cruise |
| 2 | 180 | Cruise |
| 3 | 250 | Cruise |
| 4 | 230 | Cruise |
Findings
| Finding | |
|---|---|
| 15110 | factor |
| 24032 | cause |
| 24545 | cause |
| 24101 | cause |
| 24506 | cause |
| 24551 | cause |