N31013 Lockheed L-1011 accident

NTSB MKC85IA131 · 1985-06-11 · ST. LOUIS, MO · near STL

Docket — crew, injuries and powerplant

Factual narrative

WHILE ON AN IFR APPROACH TO LAND AT STL AND THE PLT INITIATED FLAPS. THE NO.3 OUTBOARD FLAP VANE SEPARATED FROM ITS MOUNTING AND FELL TO THE GROUND. UPON SEPARATION THE FLAP VANE STRUCK THE LEADING EDGE OF THE TRAILING EDGE FLAP KNOCKING A HOLE IN THE SKIN. THE SUBSEQUENT LANDING WAS UNEVENTFUL. EXAMINATION OF THE FLAP VANE ATTACH FITTING REVEALED IT FAILED IN FATIGUE FOLLOWED BY AN OVERLOAD SEPARATION. THERE HAVE BEEN 14 RECORDED CASES OF FAILURE OF THE FLAP VANE ATTACH FITTINGS WITH 9 REPORTED SEPARATIONS FROM THE AIRCRAFT.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Instrument Meteorological Cond
Light condition
Day
Sky condition
OVC
Ceiling (ft)
700
Visibility (sm)
25
Wind direction
270
Wind speed (kt)
11
Nearest airport
ST. LOUIS
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N31013 LOCKHEED L-1011 MINR 121

Sequence of events

#OccurrencePhase
1 130 Cruise

Findings

Finding
10322 cause