N83HL Mccoy KR-2 accident

NTSB CHI85LA009 · 1984-10-06 · COLUMBUS, OH · near 2I4

Docket — crew, injuries and powerplant

Factual narrative

THE PLT REPORTED THAT DURING TAKEOFF, THE ACFT WAS CLIMBING THRU ABOUT 50 FT AGL WHEN HE FELT A VIBRATION & NOTED A LOSS OF POWER. SUBSEQUENTLY, THE ACFT TOUCHED DOWN HARD NEAR THE DEPARTURE END OF THE RWY. THE MAIN GEAR COLLAPSED, THEN THE ACFT SLID INTO A DITCH & WAS FURTHER DAMAGED. AN EXAM OF THE ACFT REVEALED THAT THE SHAFT SEAL ON THE TURBOCHARGER HAD FAILED & ALLOWED OIL TO ESCAPE INTO THE EXHAUST SYS. SUBSEQUENTLY, THE TURBO IMPELLER BECAME VERY HARD TO ROTATE.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
BKN
Ceiling (ft)
10000
Visibility (sm)
6
Wind direction
110
Wind speed (kt)
8
Temperature (F)
72
Nearest airport
BOLTON FIELD
Distance from field
0.0
Airport elevation
905

Aircraft

RegistrationMakeModelDamageFAR part
N83HL MCCOY KR-2 SUBS 091

Sequence of events

#OccurrencePhase
1 351 Cruise
2 180 Cruise
3 320 Cruise

Findings

Finding
15208 cause
17002 cause
17002 cause
14416 cause
19200 factor