N21YF Cessna T210L accident

NTSB CHI85IA042 · 1984-11-03 · WHEELING, IL · near PWK

Docket — crew, injuries and powerplant

Factual narrative

DURING A PREFLT, JUST PRIOR TO TAKEOFF, THE PLT CHECKED THE FLT CONTROLS & FULL TRAVEL OF THE CONTROLS WAS ACHIEVED. HE INITIATED THE TAKEOFF, BUT WHEN HE APPLIED BACK PRESSURE ON THE ELEVATOR CONTROL, IT WOULD ONLY MOVE ABOUT 1 INCH. HE ABORTED THE TAKEOFF WITHOUT FURTHER INCIDENT. AN EXAM OF THE ACFT REVEALED THE RIBBON WIRE, PN 1570308-1, FOR THE CONTROL YOKE ELECTRICAL SWITCHES BECAME JAMMED UNDER THE CONTROL COLUMN BEARINGS & RESTRICTED THE YOKE MOVEMENT. AN EXCESSIVE AMOUNT OF SLACK IN THE WIRE WAS NOTED. A CESSNA SERVICE LETTER, SE79-26, REGARDING 1978 & 1979 CESSNA 210 & P210 MODELS ADDRESSED THIS PROBLEM, BUT WAS NOT APPLICABLE TO PREVIOUS MODELS. N21YF WAS A 1974 CESSNA T2101. STARTING IN 1980, GUIDES WERE INSTALLED AT THE FACTORY. WHEN REMOVED, THE RIBBON WIRE WAS 33' LONG & WAS SPLIT FOR USE IN THE 1974 ACFT. THE REPLACEMENT RIBBON WIRE WAS 45' LONG, WAS NOT SPLIT & WAS MADE FOR USE IN SEVERAL MODELS OF CESSNA ACFT. THE SERVICE MANUAL HAD NO INSTRUCTIONS FOR INSTALLATION EXCEPT FOR A DIAGRAM.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
0
Nearest airport
PALWAUKEE
Distance from field
0.0
Airport elevation
647

Aircraft

RegistrationMakeModelDamageFAR part
N21YF CESSNA T210L MINR 091

Sequence of events

#OccurrencePhase
1 130 Cruise

Findings

Finding
12013 cause
10703 cause
24111 cause
24505
80200 cause