N21YF Cessna T210L accident
NTSB CHI85IA042 · 1984-11-03 · WHEELING, IL · near PWK
Docket — crew, injuries and powerplant
Factual narrative
DURING A PREFLT, JUST PRIOR TO TAKEOFF, THE PLT CHECKED THE FLT CONTROLS & FULL TRAVEL OF THE CONTROLS WAS ACHIEVED. HE INITIATED THE TAKEOFF, BUT WHEN HE APPLIED BACK PRESSURE ON THE ELEVATOR CONTROL, IT WOULD ONLY MOVE ABOUT 1 INCH. HE ABORTED THE TAKEOFF WITHOUT FURTHER INCIDENT. AN EXAM OF THE ACFT REVEALED THE RIBBON WIRE, PN 1570308-1, FOR THE CONTROL YOKE ELECTRICAL SWITCHES BECAME JAMMED UNDER THE CONTROL COLUMN BEARINGS & RESTRICTED THE YOKE MOVEMENT. AN EXCESSIVE AMOUNT OF SLACK IN THE WIRE WAS NOTED. A CESSNA SERVICE LETTER, SE79-26, REGARDING 1978 & 1979 CESSNA 210 & P210 MODELS ADDRESSED THIS PROBLEM, BUT WAS NOT APPLICABLE TO PREVIOUS MODELS. N21YF WAS A 1974 CESSNA T2101. STARTING IN 1980, GUIDES WERE INSTALLED AT THE FACTORY. WHEN REMOVED, THE RIBBON WIRE WAS 33' LONG & WAS SPLIT FOR USE IN THE 1974 ACFT. THE REPLACEMENT RIBBON WIRE WAS 45' LONG, WAS NOT SPLIT & WAS MADE FOR USE IN SEVERAL MODELS OF CESSNA ACFT. THE SERVICE MANUAL HAD NO INSTRUCTIONS FOR INSTALLATION EXCEPT FOR A DIAGRAM.
Circumstances
- Event type
- Incident
- Highest injury
- None
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- NONE
- Ceiling (ft)
- 0
- Visibility (sm)
- 15
- Wind direction
- 0
- Nearest airport
- PALWAUKEE
- Distance from field
- 0.0
- Airport elevation
- 647
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N21YF | CESSNA | T210L | MINR | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | 130 | Cruise |
Findings
| Finding | |
|---|---|
| 12013 | cause |
| 10703 | cause |
| 24111 | cause |
| 24505 | |
| 80200 | cause |